7. Place a lit lighter or match flame on or slightly above
the tip of the jet located in Step 6 while not reaching
over it. A long reach lighter or match is recommended.
8. While holding the flame on or slightly above the jet
tip as described in Step 7 above, slowly turn the key
valve or gas control knob to the left to allow a mini-
mal flow of gas to the burner and light the selected
jet. While attempting to light jet, do not substantially
increase gas supply. Excessive flow of gas before jet is
lit can cause pooling of gas and result in sudden flare
up. Failure to follow these instructions could result
in fire or explosion, which could cause property
damage, personal injury or death.
9. Once the selected jet (or other jets) is lit, continue to
keep any body parts from above the pit or burner and
slowly turn the key valve or gas control knob further
to the left to increase the flow of gas to the burner.
The other jets of the burner should ignite.
10. You may follow the same procedure described above to
light additional jets only if able to do so without reach-
ing across the burner or other jets which may ignite.
11. If the flame will not stay lit after several attempts, turn
the key valve to the off position and call your local
technician or gas supplier for service prior to re-at-
tempting to operate your appliance.
12. Once lit, use the key valve to adjust the flame to the
desired height.
TURNING OFF YOUR MATCH LIT SYSTEM
1. Use key to turn valve to OFF position by turning key
to the right.
2. Verify flame is OUT.
3. If using LP bottle/tank – turn bottle/tank to CLOSED
position.
4. Allow to cool completely, then cover the fire feature
with waterproof/weatherproof cover.
TURNING ON YOUR ELECTRONIC IGNITION SYSTEMS
WARNING: For electronic ignition models requiring pow-
er supply — a qualified, licensed electrician must install
power supply. An outdoor NEMA rated GFCI Receptacle
outlet should be installed within the interior of the enclo-
sure above grade to supply power to system.
1. STOP! Read all the safety information and warnings in the
Installation Manual before attempting to light fire feature.
2. Any cover must be removed prior to operation of
burner and must remain off during operation.
Danger: Fire or Explosion Hazard. If you smell gas,
shut off gas to the appliance, extinguish any open
flame. If odor continues, leave the area immedi-
ately. After leaving the area, call your gas supplier
or fire department. Failure to follow these instruc-
tions could result in fire or explosion, which could
cause property damage, personal injury or death.
3. Confirm that your Natural Gas or Liquid Propane sup-
ply to the appliance is open or on.
4. Before lighting, visually inspect fire feature and remove
any accumulated leaves or other combustible debris.
5. If you do not smell gas, use the key to turn the key
valve or gas control valve to the ON position by turn-
ing the key to the left.
6. Turn on power to the fire feature with switch, button,
www.Warming-Trends.com | 303 346 2224 | orders@warming-trends.com
or remote. Within 10 seconds of power application
Pilot Flame should be lit and visible. Once the pi-
lot is lit, the main burner will ignite shortly after. For
Push Button: Press push button ignition and listen for
clicking noise which indicates electrode is firing. Gas
should ignite after a few clicks.
7. Use key valve to adjust flame to desired height.
TURNING OFF YOUR ELECTRONIC IGNITION SYSTEMS
1. Turn off power to fire feature — with remote control or
wall switch.
2. Turn key valve to OFF position by turning key to the right.
3. If using LP bottle/tank — turn bottle/tank to CLOSED
position.
4. Verify flame is OUT.
5. After allowing for ample cooling time, cover the fire
feature with waterproof/weatherproof cover.
WARNING: FOR REMOTE CONTROL USE: To prevent
unwanted startup turn off power to the appliance
when not in use.
WARNING: If fire feature fails to turn off completely (small
flames still visible), turn off gas supply using the main
valve by your meter, and contact your gas supplier or
qualified technician.
WARNING: For electronic ignition systems, which have
an extended or detached valve box, the area in which the
valve box is installed must conform with all installation
requirements, including, but not limited to location, con-
struction, venting and local codes. Failure to do so may
result in property damage, personal injury, or death.
FIRESTORM
GAS LOG OWNER
INFORMATION AND
INSTALLATION
Thank you for your purchase of a FireStorm
from Warming Trends. We appreciate your business and hope
that you enjoy your FireStorm
Burner System Installation and Operating Instructions
Please read and follow the entire Warming Trends Own-
er's Guide and Instruction Manual to install and operate
your outdoor gas burner system. During the installation
of your burner system, for safe lighting, orient the
burner so that one end of it is easily reachable while
operating the key valve.
Please follow all instructions of this Owner's Manual
regarding the use of approved media coverage over
the burner. The approved media will form a bed upon
which to place the FireStorm Steel Gas Log. It is recom-
mended that a flat bed of media two inches wider and
longer than the FireStorm Steel Gas Log be formed.
INSTALLATION OF THE FIRESTORM STEEL GAS LOG
Your FireStorm Steel Gas Log may have sharp edges.
Please handle carefully or wear appropriate gloves when-
STEEL
TM
Steel Gas Log
TM
for many years to come!
TM
21

Advertisement

Table of Contents
loading

Table of Contents