  • Page 1 ® Owner’s Guide and Instruction Manual THANK YOU FOR YOUR PURCHASE! PATENTED www.warming-trends.com/patents...
  • Page 2 IMPORTANT PRODUCT WARNINGS DANGER FIRE OR EXPLOSION HAZARD If you smell gas: • Shut off gas to the appliance. • Extinguish any open flame. • If odor continues, leave the area immediately. • After leaving the area, call your gas supplier or fire department. •...
  • Page 3 AVERTISSEMENTS IMPORTANTS CONCERNANT LES PRODUITS DANGER RISQUE D’INCENDIE OU D’EXPLOSION S’il y a une odeur de gaz : • Coupez l’admission de gaz de l’arrareil. • Éteindre toute flamme nue. • Si l’odeur persiste, éloignez-vous de l’appareil et appelez immédiatement le fournisseur de gaz ou le service d’incendie.
  • Page 4: Table Of Contents

    Model # CFBT350 NG/LP with 24VIKHC Model # WTVES180 NG/LP as match lit IGNITION SYSTEMS - Standard Capacity Model # CFB60 NG/LP as match lit Model # CFBT410 NG/LP with 24VIKHC Model # WT230 NG/LP as match lit Model # CFB120 NG/LP as match lit...
  • Page 5: General Warnings And Information

    This Owner’s Guide and Instruction Manual contains critical information for the safe installation and operation of your Warming Trends fire feature. You must read this manual in its entirety prior to installation and/or operation. Failure to follow these instructions may result in property damage, personal injury, or death.
  • Page 6: Code Requirements

    13.0” W.C. plates and pans over 30” and for rectangular plates or pans (2.7399 Kpa) (3.2381 Kpa) over 40”. Warming Trends Burners, Ignitions, Media, and other PREMIUM - P24VIKSC, Minimum Maximum Accessories may be installed in Outdoor Fireplaces. The P24VIKHC...
  • Page 7: Construction Of Enclosure

    Warming Trends is not responsible for damage to enclosure for any reason WARNING: whatsoever.
  • Page 8: Clearances Diagram

    FIRE PIT CLEARANCES DIAGRAM Vertical clearance of 120” from burner to combustible structure or materials is required. Horizontal or lateral clearance of 36” between edge of burner and combustible structure or materials is required. Fire Pit Cavity Components (A) GFCI Outlet (B) Location for remote receiver (optional) (C) Pigtail plug included for easy installation (D) Electronics Box (Houses 120V - 24V Transformer)
  • Page 9 See Clearances Diagram on page 8 for in the vicinity of this or any other appliance. placement. Warming Trends® is not responsible for AVERTISSEMENT: Une installation, un any damages to the capstone.
  • Page 10: Match Lit System Connection Diagrams

    Leave this Connection Diagram with end user. MATCH LIT SYSTEM CONNECTION DIAGRAMS 249K BTU Systems and below 1. LOCATE FK1 Parts include Whistle-Free Flex Line, key valve, escutcheon plate, and keys. STEP 1 - FIT180 3” Key 12” Key ½” x 2” Nipple Escutcheon Key Valve EP 3...
  • Page 11 MATCH LIT SYSTEM INSTALLTION 249K BTU SYSTEMS AND BELOW CONTINUED 4. CONNECT WHISTLE-FREE FLEX LINE (FK1) Connect the Whistle-Free Flex Coupling Line to the Flared Fitting previously attached to the coupling on the bottom of the aluminum plate. Plate Flared Fitting Whistle-Free Flex Line STEP 5...
  • Page 12: Match Lit System Connection Diagrams

    MATCH LIT SYSTEM CONNECTION DIAGRAMS 250K - 300K+ BTU Systems 1. LOCATE FK2 Parts include two Whistle-Free Flex Lines, key valve, escutcheon plate, and keys. STEP 1- FIT250 3” Key 12” Key STEP 1- FIT250 Escutcheon Key Valve (2) 3/4” x 3” Nipple (2) 3/4”...
  • Page 13 MATCH LIT SYSTEM INSTALLTION 250K - 300K+ BTU SYSTEMS CONTINUED 4. CONNECT FLARED FITTINGS TO 3/4” TEE (FK2) Connect Flared Fittings to 3/4” Tee. Coupling Plate (½” x 3/4” Reducing Fitting) or (3/4” x 3” Nipple) Flared Fitting Flared Fitting (3/4”...
  • Page 14: Volt Electronic Ignition System Connection Diagrams

    24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 249K BTU Systems 1. LOCATE FK1 Parts include Whistle-Free Flex Line, key valve, escutcheon plate, and keys. STEP 1 - FIT180 3” Key 12” Key ½” x 2” Nipple Escutcheon Key Valve Whistle-Free Flex Line TEP 3 2.
  • Page 15 STEP 5 24 VOLT ELECTRONIC IGNITION SYSTEM INSTALLATION 249K BTU SYSTEMS AND BELOW CONTINUED 4. LOCATE 2ND FLARED FITTING AND CONNECT TO KEY VALVE Flared Fitting Key Valve (FK1) Locate the other Flared Fitting removed in Step 2 and connect into the Key Valve, placing the non-flared end into the key valve.
  • Page 16: Volt Electronic Ignition System Connection Diagrams

    24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K - 300K+ BTU Systems 1. LOCATE FK2 Parts include two Whistle-Free Flex Lines, key valve, escutcheon plate, and keys. STEP 1- FIT250 3” Key 12” Key STEP 1- FIT250 Escutcheon Key Valve (2) 3/4”...
  • Page 17 24 VOLT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K - 300K+ BTU SYSTEMS CONTINUED 4. CONNECT FLARED FITTINGS TO 3/4” TEE (FK2) Connect 3/4” Tee Flared Fitting to ½” x 3/4” Reducing Fitting or 3/4” x 3” Nipple. Apply thread Then connect Flared Fittings to Coupling sealant here 3/4”...
  • Page 18 24 VOLT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K - 300K+ BTU SYSTEMS CONTINUED 6. CONNECT FIT KIT TO KEY VALVE AND FLARED FITTINGS Flared Fitting (FK2) Connect 3/4” x 3” Nipple to Key Valve. Apply thread sealant here Then connect the 3/4” Tee to the Key Valve connection just made.
  • Page 19: Push Button Ignition System Connection Diagrams

    PUSH BUTTON IGNITION SYSTEM CONNECTION DIAGRAMS Up to 300K BTU Systems 1. TO PLACE THE SPARK IGNITER IN .125” THE PROPER POSITION, INSTALLER WILL NEED TO DRILL A HOLE IN THE PLATE. Spark CROSSFIRE Igniter Measure where to drill hole by holding Brass Burner Stem tip of Spark Igniter no further than...
  • Page 20: Media Installation

    MEDIA INSTALLATION For Ceramic Log Sets: Place logs on top of lava rock or media base Only use approved decorative media (glass, lava rock, according to preference ceramic log sets, etc.) that have been manufactured for and desired flame pattern. specific use in fire features.
  • Page 21: Firestorm Steel Gas Log Owner Information And Installation

    Thank you for your purchase of a FireStorm Steel Gas Log WARNING: For electronic ignition models requiring from Warming Trends. We appreciate your business and power supply – a qualified, licensed electrician must hope that you enjoy your FireStorm for many years to come! install power supply.
  • Page 22: General Maintenance

    the burner is centered underneath it. Your steel log has of gas before jet is lit can cause pooling of gas and a “lighting opening” at each end to aid in lighting the result in sudden flare up. Failure to follow these burner.
  • Page 23: Troubleshooting

    • No Pilot Flame - Pilot sparks or glow plug glows but JET ORIFICE CLEANING pilot won’t light. Annual inspection and cleaning of the fire feature is o Air in the gas line. If this is a new install it may take recommended.
  • Page 24: Warranty

    Mercury Ignition Instruction Manual or as otherwise approved by We offer a lifetime, full warranty for our Burners, regardless of Warming Trends, in writing, prior to sale. In the event a system must be ownership, beginning on the date of purchase (“Warranty Period”). This...
  • Page 25: Prop 65 Warning

    PROP 65 WARNING What is “Prop 65”? Carbon Monoxide: Carbon monoxide is a colorless, odorless, Proposition 65 (“Prop 65”) is a California law which requires and poisonous gas. It is formed during the combustion of businesses to provide warnings to Californians about various fuels.
  • Page 26: Replacement Parts

    Premium 24 Volt 512K BTU High Capacity Control Box with Dual Pilot Connections www.warming-trends.com/patents This Owner's Guide and Instruction Manual contains critical information for the safe installation and operation of your Warming Trends fire feature. You must read this manual in its entirety prior to installation and/or operation. Failure to follow PATENTED these instructions may result in property damage, personal injury, or death.
  • Page 27 Whatever your question, our team is happy to help. Call our Flame Specialists at (303) 346-2224 or email them at Orders@Warming-Trends.com. For more information about Warming Trends products, please visit us at www.Warming-Trends.com SCAN QR CODE TO RESOURCES ON WARMING-TRENDS.COM www.Warming-Trends.com | 303 346 2224 | orders@warming-trends.com...
  • Page 28 Contact Warming Trends 1050 West Hampden Avenue, Suite 200 Englewood, Colorado 80110 303.346.2224 | Orders@Warming-Trends.com Tag us on Instagram with your Finished Projects! @WarmingTrends...