Connection Pipe Requirement - Gree GKH24S3GI Owner's Manual

Dc inverter cassette type unit
Hide thumbs Also See for GKH24S3GI:
Table of Contents

Advertisement

3.2.2 Outdoor Unit
①. Install the unit where it will not be tilted by more than 5° .
②. During installation, if the outdoor unit has to be exposed to strong wind, it must be fixed securely.
If possible, do not install the unit where it will be exposed to direct sunlight. (If
necessary, install a blind that does not interfere with the air flow.)
Install the outdoor unit in a place where it will be free from being dirty or getting wet
by rain as much as possible.
Install the outdoor unit where it is convenient to connect with the indoor unit.
Install the outdoor unit where the condensate water can be drained out freely
during heating operation.
Do not place animals and plants in the path of the warm air.
Take the air conditioner weight into account and select a place where noise and
vibration are small.
Install the outdoor unit where is capable of withstanding the weight of the unit and
generates as less noise and vibration as possible.
Provide the space shown in Fig. 3.2, so that the air flow is not blocked. Also for
efficient operation, leave three of four directions of peripheral constructions open.

3.3 Connection Pipe Requirement

The maximum length of the connection pipe is listed in the Table below. Do not place the units between
which the distance exceeds the maximum length of the connection pipe.
DC Inverter U-match Series Cassette Type Unit
WARNING!
> 2000mm
(6-5/9feet)
Fig. 3.2
CAUTION!
7
> 500mm
(1-2/3feet)

Advertisement

Table of Contents
loading

Table of Contents