18
Select the step depending on your purpose for a created volume.
To create a new volume:
(1) Right-click the new dynamic disk and select New Volume. (2) Follow the instructions on the screen to create a
new volume.
To restore a RAID 5 volume (RAID resynchronization):
(1) Right-click the volume labeled "Failed Redundancy" and click Restore Volume. (2) When "Select the disk from the
following list" is displayed, select the drive to restore and click OK. Perform steps (1) and (2) for each volume that
requires RAID resynchronization. (3) Right-click the volume labeled "Missing" and select Delete Disk.
To restore a Mirrored volume (RAID resynchronization):
(1) Right-click the volume labeled "Failed Redundancy" and click Remove Mirror. (2) When "Remove Mirror" is
displayed, select the drive with its status missing and click Remove Mirror. (3) In "Disk Management", click OK.
Perform steps (1) to (3) for each volume that requires RAID resynchronization. (4) Select the new volume where
mirroring will be performed and select Add Mirror. (5) When "Add Mirror" is displayed, select the drive where
mirroring will be performed with the selected volume and click Add Mirror. (6) When "Disk Management" is
displayed, click OK.
Hard Drive Replacement in Case of Disk Failure on Drive 1 or Drive 2
1
Shut down the TeraStation.
2
WS5600DR2, WS5400DR2, WS5200DR2: Open the front cover with the included key.
3
Push the unlock button of the failed hard drive and swing the lock mechanism out.
4
Pull out the drive cartridge and remove it from the TeraStation.
5
Insert the new drive in the empty slot. Slide the drive in with the locking mechanism open.
6
Swing the lock back down until it clicks into place.
36

Advertisement