Appliance Preparation; Vent Collar Preparation; Prepare For Heat Management - Majestic DVLINEAR36 Installation Manual

Table of Contents

Advertisement

6
6

Appliance Preparation

A. Vent Collar Preparation
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
Top Vent
WARNING! Risk of Fire! Do not remove heat shield.
Elevated header temperatures may cause a fire.
1. Remove two screws and discard. See Figure 6.1.
2. Fold up top heat shield to 90 degrees as shown in
Figure 6.2.
REMOVE SCREWS
Figure 6.1 Heat Shield Shipping Position
HEAT MANAGEMENT
KNOCKOUT LOCATIONS
Figure 6.2 Top Heat Shield in Position
Hearth & Home Technologies • DVLINEAR36 Installation Manual • 2569-980 Rev. E • 11/20
38
TOP HEAT SHIELD
IN POSITION
B. Prepare For Heat Management
Introduction
An optional heat management system allows the heat from
the appliance to be redirected as desired.
An optional heat management system must be installed by
a qualified service technician at the time of the appliance
installation. Follow the instructions shipped with the kit for
installation and operation.
Heat Managment Option:
• Passive Heat (PH-FRT-LINEAR, PH-SIDE-LINEAR):
The heat is vented into the room in which the appliance
is installed through a discharge opening(s).
NOTICE: Additional clearances are required for heat
management systems installations. Provisions must be
made in advance to ensure fit within the framing.
• Determine the heat management system(s) that will be
installed.
• Locate the two heat management knockouts on the top of
the appliance. See Figure 6.2. Remove the knockouts
from the appliance with a tin snips.
• Center the duct collar or passive heat adapter around
the exposed hole and attach it to the appliance.
Note: Do this BEFORE final positioning of the appliance.
• Determine the location for the air register/fan housing
assembly.
WARNING! Risk of Fire! DO NOT block passive heat
registers!
Overheating of appliance and combustible
materials will occur.
WARNING! Risk of Fire! DO NOT remove a knockout
unless a heat management system will be installed in its
place. Appliance and combustible materials will overheat.
REMOVE HEAT MANAGEMENT KNOCKOUTS
Figure 6.3 Heat Management Knockout Locations

Advertisement

Table of Contents
loading

Table of Contents