SECTION 8
AC INPUT
Nominal AC Input Voltage
Input Current
Input Current at No Load
Inrush current at Startup
DC OUTPUT
Output Voltage
Output Current
Output Noise and Ripple
Peak Efficiency
DESIGN
Type
Output Side Switching
Frequency
PROTECTIONS
Short Circuit, Overload
Over Voltage
Over Temperature
COOLING
Type of cooling
FUSE
Internal AC Side Fuse,
120VAC Input
NOTE: Specifications are subject to change without notice.

| Specifications

SEC-1212
120 VAC (100-130 VAC), 50/60 Hz : Factory Preset, or
230 VAC (200 - 260 VAC), 50/60 Hz : By internal jumper setting
2.5 A @ 120 VAC
20A +/- 5A for < 5 ms
• Continuous: 10A
• Current Limit: 14A, Auto recovery
Switch Mode Power Supply (SMPS) with Fixed Frequency Pulse Width
20 KHz
Constant Current Limiting at 14A;
Auto Reset
Cooled by convection. No protec-
tion is necessary
Convection – No fan
5 mm x 20 mm Glass Fuse
250V, 3A, Time Delay Type
LittelFuse - "239003"
120 mA ± 10% @120VAC
13.8VDC ± 0.1V
• Continuous: 23A;
• Current Limit: 25A, Auto recovery
< 150 mV Peak to Peak
85% +/-5%
Modulation (PWM)
Constant Current Limiting at 25A;
Regulated by PWM Controller
Output shuts down when Power
Transformer winding temperature
≥ 105°C ± 5°C / 221°F ± 9°F; Auto
reset on cooling down to ≤ 75°C ±
Temperature controlled fan. ON
when Power Transformer winding
temperature is ≥ 60°C ± 5°C / 140°F
± 9°F; OFF when cools down to ≤
40°C ± 5°C / 104°F ± 9°F
5 mm x 20 mm Glass Fuse
250V, 6.3A, Time Delay Type
LittelFuse - "21806.3"
SAMLEX AMERICA INC. | 19
SEC-1223
5.5A @ 120 VAC
30A +/- 5A for < 5 ms
25 KHz
Auto Reset
5°C / 167°F ± 9°F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Samlexpower sec-1212Samlexpower sec-1223-sm

Table of Contents