Installation - Samlexpower SEC-1223 Owner's Manual

Switch mode dc power supplies
Hide thumbs Also See for Samlexpower SEC-1223:
Table of Contents

Advertisement

SECTION 4
4.1
WARNING!
1. Before commencing installation, please read the safety instructions
explained in Section 1 titled "Important Safety Instructions".
2. It is recommended that the installation should be undertaken by a
qualified, licensed / certified electrician.
3. Various recommendations made in this manual on installation will be
superseded by the National / Local Electrical Codes related to the loca-
tion of the unit and the specific application.
MISE EN GARDE!
1. Avant de commencer l'installation, veuillez lire les instructions de sécurité
a expliqué à la section 1 intitulée "Instructions de sécurité importantes".
2. Il est recommandé que l'installation doit être effectuée par un tech-
nicien qualifié, autorisé / électricien certifié.
3. Différentes recommandations faites dans ce manuel sur l'installation
sera remplacée par la National / les codes électriques locaux liés à
l'emplacement de l'unité et l'application spécifique.
4.2 INSTALLATION DIMENSIONS
Refer to Section 2, Figs 2.1 for installation dimensions for SEC-1212 and Section 2, Fig 2.2
for installation dimensions for SEC-1223 .
4.3 LOCATION OF INSTALLATION
Please ensure that the following requirements are met:
Working Environment: Indoor use.
Cool: Heat is the worst enemy of electronic equipment. Hence, please ensure that the
units are installed in a cool area that is also protected against heating effects of direct
exposure to the sun or to the heat generated by other adjacent heat generating devices.
Well ventilated: SEC-1212 is cooled by convection and has ventilation openings on
the sides. SEC-1223 is cooled by convection and by forced air-cooling by temperature
controlled fan on the bottom of the unit. The fan at the bottom of SEC-1223 draws cool
air from air intake openings on the sides and discharges hot air through the exhaust
openings under the fan. To avoid shut down of the units due to over temperature, do
not cover or block the ventilation / suction / exhaust openings or install the units in an
area with limited airflow. Keep a minimum clearance of 10" around the units to provide
adequate ventilation. If installed in an enclosure, openings must be provided in the
enclosure, directly opposite to the air-suction and air-exhaust openings of the unit.
Dry: There should be no risk of condensation, water or any other liquid that can enter
or fall on the units.