Specifications - Samlexpower SEC-1223BBM Owner's Manual

Switch mode dc power supply with battery backup
Table of Contents

Advertisement

SeCtIOn 9 |
cAteGoRY
Input Voltage
Input Current
AC INPUT
Input Current at No Load
Inrush current at Startup
Output Voltage at Load Terminals
Output Voltage at Battery
Terminals (Without battery)
Output Voltage at Battery
Terminals (With battery)
Output Voltage Noise and Ripple
Continuous Output Current at
Load Terminals
DC oUTPUT
Continuous Output Current at
Battery Terminals (Battery Backup)
Output Current Limit at Load
Terminals
Output Current Limit at Battery
Terminals (Battery Backup)
Peak Efficiency
ExTErNAL
Type & Voltage
BACKUP BATTErY
Capacity
Short Circuit, Overload
Over Voltage
Over Temperature
ProTECTIoNS
(Power Supply Section)
CooLING Forced Air
Internal AC Side Fuse
External Battery Side Fuse (By User) - 32V, 25 A, Fast Acting
fUSES
External Load Side Fuse (By User)
Safety
CoMPLIANCE
Electro Magnetic Interference EMI

Specifications

PARAMeteR
SPeciFicAtion
120 VAC Nominal (+6% / -10%), 50/60 Hz
5.5A @ 120 VAC
53 mA ± 10%
28A ±5% for 2.8 ms
13.8VDC ± 0.1V
13.8VDC ± 0.1V
Actual battery voltage corresponding to
State of Charge; 13.5V ± 0.2V when battery is
fully charged and floating
< 150 mV Peak to Peak
19A (With battery backup);
23A (Without battery backup)
Up to 4A (When battery is completely discharged
to Standing Voltage of 11.4V)
- 25A for 100 sec (External 25A fuse will blow)
- Surge > 25A as permitted by Time Current
Characteristics of 25A load side fuse (In Battery
backup Mode)
4A (When battery is completely discharged to
Standing Voltage of 11.4V)
85% ± 5%
Lead Acid, 12V
40Ah to 100 Ah
External 25A Fuse will blow
Regulated by PWM Controller
Output of Power Supply Section shuts down when
Power Transformer winding temperature ≥ 105°C
± 5°C / 221°F ± 9°F); Auto reset on cooling down
to ≤ 75°C ± 5°C / 167°F ± 9°F
Temperature controlled fan. ON when Power
Transformer winding temperature is ≥ 60°C ± 5°C
/ 140°F ± 9°F; OFF when cools down to ≤ 40°C ±
5°C / 104°F ± 9°F
- 5 mm x 20 mm Glass Fuse
- 250V, 6.3A, Time Delay Type
- Bussmann: "GDC-6.3"; LittelFuse - "21806.3"
- Within 7" of the Battery Positive Post
- 32V, 25 A, Fast Acting
- Within 7" from Load Terminal of the unit
UL safety listed as "Information Technology Equip-
ment Power Supply" for USA (UL Standard ANSI/
UL-60950-1) and for Canada (CSA Standard CAN/
CSA-C22.2 No. 60950-1)
FCC Part 15(B), Class B
SAMLEX AMERICA INC. | 21