SECTION 8
AC INPUT
Nominal AC Input Volt-
age
Input Current
Input Current at No Load
Inrush current at Startup
DC OUTPUT
Output Voltage
Output Current
Output Noise and Ripple
Peak Efficiency
Output Metering
DESIGN
Type
Output Side Switching
Frequency
PROTECTIONS
Short Circuit, Overload
Over Voltage
Over Temperature
COOLING
Forced Air
| Specifications
SEC-1235
120 VAC (100-130VAC), 50/60 Hz : Factory Preset
230VAC (200 – 260VAC), 50/60Hz: By internal
7.5 A @ 120 VAC; 3.5A @ 230VAC
•
•
Switch Mode Power Supply (SMPS) with Fixed Frequency
Constant Current Limiting at 35A; Auto Reset
Regulated by PWM Controller
Output shuts down when Power Transformer winding
temperature ≥ 105°C ± 5°C / 221°F ± 9°F; Auto reset on
cooling down to ≤ 75°C ± 5°C / 167°F ± 9°F
Temperature controlled fan. ON when Power Transformer
winding temperature is ≥ 60°C ± 5°C / 140°F ± 9°F;
OFF when cools down to ≤ 40°C ± 5°C / 104°F ± 9°F
jumper setting
120 mA ± 10% @120VAC
30A +/- 5A for < 5 ms
13.8VDC ± 0.1V
Continuous: 30A;
Current Limit: 35A, Auto recovery
< 150 mV Peak to Peak
85% +/-5%
-
Pulse Width Modulation (PWM)
30.5 KHz
SEC-1235M
Voltmeter and Ammeter
SAMLEX AMERICA INC. | 19