Specifications - Samlexpower SEC-1235CE Installation & Operating Manual

Switch mode dc power supply
Table of Contents

Advertisement

Model No.
Nominal Input Voltage
Input current
Output Voltage
Output voltage adjustment
Output current
Current limit
No load current draw
Ripple
Noise
Peak Efficiency
Cooling
Protections against
Operating temperature
Safety compliance
• Standards
EMI/EMC compliance
• Standards
AC input connections
DC output connections
Input side fuse
(5 mmX20mm, glass ferrule, Manufacturer: Ltttel Fuse, Model 218004
delayed action)
Weight
Dimensions (L X W X H)
Note:
The above specifications are subject to change without notice

SPECIFICATIONS

SEC-1235CE
230 VAC, 50Hz (Range: 207 to 253 VAC)
3.5 A at 230 VAC
13.8 VDC
11.5 V to 15.5 V with the help of internal potentiometer
30 A continuous
35 A, constant current limiting, auto recovery
130 mA at 230 VAC, 50 Hz
50 mV peak to peak
150 mV peak to peak
85%
Temperature controlled fan
Overload, short circuit
Over temperature
0° to 40° C
Comforms to European Low Voltage Directive 2006/95/EC
• IEC 60950-1; EN 60950-1
Comforms to European EMC Directive 2004/108/EC
• EN 55022 (class B); EN 61000-3-2; EN 61000-3-3
• EN 55024 :
EN 61000-4-2 to 6; EN 61000-4-8; EN 61000-4-11
Male AC inlet connector Type "IEC 320-C14"
Detachable AC power cord with:
• Female connector Type "IEC 320-C13" on one end to
mate with AC power inlet connector on the power supply
• Male, 2 pole, 3 Wire grounding plug Type EU1-16P
(CEE 7/7) (Schuko) on the other end for connection to the
AC outlet.
RED (+) and BLACK (-) terminals with tubular hole and set
screw. Hole diameter 0.2 ", (5 mm). Includes a pair of copper
terminal lugs for crimping to output wires to the load
250V, 4 A
3.4 lbs
8" X 7.3" X 2.5"
11.

Advertisement

Table of Contents
loading

Table of Contents