Wenglor P1KY0 Series Operating Instructions Manual

Wenglor P1KY0 Series Operating Instructions Manual

High-performance distance sensors

Advertisement

EN
P1KY0xx
High-Performance Distance Sensors
Operating Instructions
Translation of the Original Operating Instruction
Subject to change without notice
Available as PDF version only
Version: 1.1.0
Status: 01.04.2019
www.wenglor.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P1KY0 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wenglor P1KY0 Series

  • Page 1 P1KY0xx High-Performance Distance Sensors Operating Instructions Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version: 1.1.0 Status: 01.04.2019 www.wenglor.com...
  • Page 2: Table Of Contents

    Table of Contents 1. General ...........................3 1.1 Information Concerning these Instructions ..................... 3 1.2 Explanations of Symbols ......................... 3 1.3 Limitation of Liability ..........................4 1.4 Copyrights ..............................4 2. For Your Safety ........................5 2.1 Use for Intended Purpose ........................5 2.2 Use for Other than the Intended Purpose ....................
  • Page 3: General

    • The product is subject to further technical development, and thus the information contained in these operating instructions may also be subject to change. The current version can be found at www.wenglor.com in the product’s separate download area. NOTE! The operating instructions must be read carefully before using the product and must be kept on hand for later reference.
  • Page 4: Limitation Of Liability

    • wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instruc- tions, unless wenglor was verifiably aware of such errors at the point in time at which the operating instruc- tions were prepared.
  • Page 5: For Your Safety

    • The product is not suitable for use in potentially explosive atmospheres. • The product may only be used with accessories supplied or approved by wenglor, or combined with approved products. A list of approved accessories and combination products can be accessed at www.wenglor.com on the product detail page.
  • Page 6: Personnel Qualifications

    • In the event of possible changes, the respectively current version of the operating instruc- tions can be accessed at www.wenglor.com in the product’s download area. • Read the operating instructions carefully before using the product.
  • Page 7: Technical Data

    3. Technical Data Optical Data Working range 0…1000 mm Setting range 100…1000 mm Switching hysteresis < 20 mm Light source Laser (red) Wavelength 680 nm Service life (ambient temp. = +25° C) 100000 h Laser class (EN 60825-1) Beam Divergence <...
  • Page 8: Spot Diameter

    P1KYxxx Order Nr. Technical Data Mounting technology no. Cable Cable Cable Cable Cable Cable 200 mm 200 mm 200 mm 200 mm 200 mm 200 mm Cable, M8×1, with with M8×1, with with M8×1, with with Connection 4-wire, 4-pin plug plug 4-pin plug...
  • Page 9: Switching Distance Deviation

    = change in switching distance Black, 6 % remission Gray, 18 % remission 3.3 Accessory Products wenglor can provide you with suitable connection technology for your product. Suitable mounting technology no. Suitable connection technology no. IO-Link master P1KY005 – P1KY007 and P1KY12 – P1KY014 wTeach2 software DNNF005 P1KY005 –...
  • Page 10: Layout

    3.4 Layout P1KY001 P1KY002 Technical Data...
  • Page 11 P1KY003 P1KY004 1 = receiver diode 2 = emitter diode M3 screw = 0,5 Nm Dimensions specified in mm (1 mm = 0.03937”) High-Performance Distance Sensors...
  • Page 12 P1KY005 and P1KY012 P1KY006, P1KY013 Technical Data...
  • Page 13 P1KY007, P1KY014 1 = receiver diode 2 = emitter diode M3 screw = 0,5 Nm Dimensions specified in mm (1 mm = 0.03937”) High-Performance Distance Sensors...
  • Page 14: Control Panel

    3.5 Control Panel P1KY001 – P1KY004 05 = Switching Distance Adjuster 30 = Switching Status Display/Contamination Warning 68 = supply power indicator P1KY005 – P1KY007 and P1KY012 – 014 A 23 5a 68 6a 06 = teach-in key 5a = switching status display, A1 6a = switching status display, A2 68 = supply power indicator 3.6 Scope of Delivery...
  • Page 15: Transport And Storage

    4. Transport and Storage 4.1 Transport Upon receipt of shipment, the goods must be inspected for damage in transit. In the case of damage, con- ditionally accept the package and notify the manufacturer of the damage. Then return the device, making reference to damage in transit.
  • Page 16: Installation And Electrical Connection

    5. Installation and Electrical Connection 5.1 Installation • Protect the product from contamination during installation. • Observe all applicable electrical and mechanical regulations, standards, and safety rules. • Protect the product against mechanical influences. • Make sure that the sensor is mounted in a mechanically secure fashion. •...
  • Page 17 DANGER! Risk of personal injury or property damage due to electric current! Voltage conducting parts may cause personal injury or damage to equipment. • The electric device may only be connected by appropriately qualified personnel. High-Performance Distance Sensors...
  • Page 18: Diagnostics

    5.3 Diagnostics P1KY001 – 004 Causes for Triggering the Error Messages (blinking LED at approx. 2,5 Hz): Display LED Diagnosis/Cause Elimination Contamination Carefully clean the optic cover with a cloth. Continuous blinking • Increase the sensor’s switching distance. at approx. 2.5 Hz Unreliable working range •...
  • Page 19 • Shut down the machine. • Analyze and eliminate the cause of error with the help of the diagnostics information. • If the error cannot be eliminated, please contact wenglor’s support department. • Do not operate in case of indeterminate malfunctioning.
  • Page 20: Settings

    6. Settings P1KY001-004 (sensors with potentiometer) The switching point is precisely adjusted at the potentiometer with the help of a screwdriver. When turning the potentiometer to the limit stop, it must be assured that torque remains below the destruction limit of 40 Nm. Object Detection Directly in Front of the Background or Underlying Surface •...
  • Page 21 P1KY005-007 and P1KY012-014 (Sensors with Teach-in) The switching distance to the object can be taught in for both outputs by pressing the teach-in key on the sensor (foreground teach-in). Sensor Teach-in distance Object Switching point Foreground Teach-In for Switching Output 1 1.
  • Page 22: Settings Via Io-Link

    In addition to foreground teach-in (default setting), there’s also a background teach-in option for both outputs. Additionally, there’s also a window teach-in option for both outputs. Process and parameters data, as well as the interface protocol and the IODD, can be found at www.wenglor.com in the product’s separate download area.
  • Page 23: Locking

    7.3 Locking If 18 to 30 V DC is continuously applied to the teach-in input, the teach-in key is locked and protected against inadvertent changes. 1. Change the A1/A2 pin function to external teach-in. 2. Permanently connect pin A2 to voltage within a range of 18 to 30 V DC. 3.
  • Page 24: Test Mode

    • Do not clean the sensor with solvents or cleansers which could damage the product. • The product must be protected against contamination during initial start-up. 9. Proper Disposal wenglor sensoric GmbH does not accept the return of unusable or irreparable products. Respectively valid national waste disposal regulations apply to product disposal. Maintenance Instructions...
  • Page 25: Appendix

    “3.2 Switching Distance Deviation” on page 9 “5.2 Electrical Connection” on page 16 10.3 EU Declaration of Conformity The EU declaration of conformity can be found on our website at www.wenglor.com in the product’s down- load area. High-Performance Distance Sensors...

Table of Contents