1. Confirm that the inlet gas pressure is
between the minimum and maximum
pressures allowed for this boiler.
2. Disconnect electrical power to the boiler.
3. Turn off the boiler's gas supply by turning
off the gas control valve.
4. Remove the boiler's front panel. For
details, see section "3.7 How to Remove
the Front Panel."
5. Remove the air supply damper:
Unclip the Velcro piece
Lift up the air supply damper to
remove and gently place aside
6. Unscrew the gas valve and gas venturi
connections.