Reset Selection When The Input • Prime Signal Is On - TEC B-672 Maintenance Manual

Hide thumbs Also See for B-672:
Table of Contents

Advertisement

6. DIAG. TEST OPERATION
6.3.18 Reset Selection when the INPUT • PRIME Signal is ON.
Reset ON/OFF when the INPUT • PRIME signal ON is selected.
< 1
< 2
I N
signal is ON" with the [FEED] key
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enable.
2. A changed "Reset ON/OFF when the INPUT • PRIME signal is ON" is stored in memory by
Mantenimiento Periféricos Informáticos C/Canteras,15 28860 Paracuellos de Jarama Madrid Tel: 91 748 16 04 www.mpi.com.es
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
>
D I A G N
I C .
O S T
Press the [FEED] key.
>
P A R A M
R
E T E
Press the [PAUSE] key 20 times.
P
U T
P R
I M E
Select the "Reset ON/OFF
when the INPUT • PRIME
or [RESTART] key.
Press the [PAUSE] key.
pressing the [PAUSE] key.
V
1 . O A
S E T
O N
• ON:
The printer will restore to the initial status.
• OFF: The printer will not restore to the initial status.
6-40
EM18-33017
(Revision Date: Dec. 10 '99)
6.3 PARAMETER SETTING MODE

Advertisement