6. DIAG. TEST OPERATION
6.3.3
< 1
< 2
B A
NOTES:
Mantenimiento Periféricos Informáticos C/Canteras,15 28860 Paracuellos de Jarama Madrid Tel: 91 748 16 04 www.mpi.com.es
Back Feed Length Fine Adjustment
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
>
D I A G N O S T I C
Press the [FEED] key.
>
P A R A M E T E R
Press the [PAUSE] key three times.
C
K
F E E D
A D J . + 0 . 0 m m
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds
enables a fast forward.
2. Max. fine adjustment ± 9.9 mm = Key fine adjustment value ( ± 9.5 mm) + PC fine
adjustment value ( ± 9.9 mm).
When the value reaches the maximum, the value remains unchanged even if the
subsequent fine adjustment is performed.
3. A changed back feed value is stored in memory by pressing the [PAUSE] key.
V 1 . O A
S E T
[FEED] key:
[RESTART] key: Pressing the [RESTART] key one
Press the [PAUSE] key.
Continued on Section 6.3.4
X axis fine adjustment.
6-17
EM18-33017
6.3 PARAMETER SETTING MODE
Pressing the [FEED] key one time
is a -0.5 mm change, up to -9.5
mm. (See NOTE 2.)
time is a +0.5 mm change, up to
+9.5 mm. (See NOTE 2.)