  • Page 1 Master Unit EKOAX IPC-M User Manual File Release Date Author Access IPC-M_UserManual_V1.0.docx 2017/04/27 Ekselans Confidential...
  • Page 2: Table Of Contents

    2.7. System Menu ....................................... 46 2.7.1. Information ....................................46 2.7.2. Running Status ..................................... 47 2.7.3. Slave Type ....................................49 2.7.4. IP Access Control ..................................51 2.7.5. System Time ....................................51 2.7.6. System Log ....................................52 2 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 3 IPCOAX IPC-M User Manual V001 2.7.7. Account ....................................... 53 2.7.8. Reboot ......................................53 2.7.9. Factory ......................................55 2.7.10. Upgrade ..................................... 55 2.7.11. Backup Restore ..................................55 2.8. Exit Menu ......................................56 Master Unit EKOAX IPC-M Confiential 3 of 61...
  • Page 4: Introduction

    Hardware requirement: CPU PIII 800 MHz, 256M RAM memory, 1 GB disk space and 10/100M Ethernet interface. • 1.2. Functional Features The web management interface supports the functions shown in the following table: 4 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 5 IP addresses from where the access is allowed. System Time To setup date and time of the system. System Log To display the system log and set the log options. Account To manage the administrator account. Master Unit EKOAX IPC-M Confiential 5 of 61...
  • Page 6: Web Management Interface Reference

    IPC-M master unit. 2.1. Login This topic describes the procedure to login to the web interface. The following table shows the default parameters needed to connect to IPC-M web interface. 6 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 7 1. Enter http://192.168.1.2 in the address bar of the web browser (192.168.1.2 is the default IP address of the MGMT Ethernet interface of the IPC-M unit) and press Enter to display the login interface, as shown in Picture Master Unit EKOAX IPC-M Confiential 7 of 61...
  • Page 8: Web Interface Introduction

    2. In the login interface, enter the user name and password. For the details about the default setting of the user name and password, see Table. 2.2. Web interface introduction After successfully login, web interface shows a web page as shown in Picture 8 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 9 ◦ Serial number ◦ MAC address of the main system block. ◦ MAC address of Ethernet over coaxial cable block. ◦ Number of online slave units (IPC-S). • Device information: it includes Master Unit EKOAX IPC-M Confiential 9 of 61...
  • Page 10: Slave Menu

    This list is shown in the Slave Authorization table and it is also called the White List. 10 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 11 ). The Slave Type combo box displays a list of type 2.7.3 as shown in Picture . For more information about the available Slave Types, you can go to the SYSTEM→ SLAVE_TYPE menu. The type is usually detected automatically by the IPC-M. Master Unit EKOAX IPC-M Confiential 11 of 61...
  • Page 12 • Slave MAC address, • Slave Type, • Starting Time: currently not used. Please, keep value to 00:00. • Ending Time: currently not used. Please, keep value to 23:59. • Authorization Enable, 12 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 13: Slave Basic Information

    (the white list) the related slave management page is displayed as it is shown in Picture Picture On the top of the page, you can see the available sub-menus: • Slave Basic Information • Slave Configuration Information • Slave MAC Table Master Unit EKOAX IPC-M Confiential 13 of 61...
  • Page 14: Wifi Basic Configuration

    Virtual Server Configuration • WiFi Management • WiFi Upgrade Some of these sub-menus cannot be available for some types of slaves. The following table shows the available menus depending on the Slave types defined. 14 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 15: Lan Configuration

    LAN Configuration Static Route Configuration L2 Switch Configuration Virtual Server Configuration WiFi Management WiFi Upgrade Table 2.3.1.1. Slave Basic Information The following table describes the items displayed in this page. See Picture. Master Unit EKOAX IPC-M Confiential 15 of 61...
  • Page 16 Template Selection: the user can select here the slave template to apply to the slave. The template can configure in the SLAVE→Template menu (see 2.3.3 • Template configuration: the user can configure the slave and save the configuration as a private template for the slave. 16 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 17 Current Configuration: it shows the current status of the slave configuration related • to the internal ports available (see Port Number item in Table). Picture The following table describes the items displayed in this page: Master Unit EKOAX IPC-M Confiential 17 of 61...
  • Page 18 Speed & Duplex This is the column in the slave internal ports table where you can set the speed and duplex mode of each port. The available values in the related combo boxes are: 18 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 19 Current Configuration pane. 100M/Full – 100 Mbps in full-duplex mode 10M/Full – 10 Mbps in full-duplex mode. 100M/Half – 100 Mbps in half-duplex mode 10M/Half – 10 Mbps in half-duplex mode Master Unit EKOAX IPC-M Confiential 19 of 61...
  • Page 20 This value must be between 1 and 4095. A packet with a VLAN ID matching PVID is inserted in the frame forwarded through the port. 20 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 21 The column to check which internal ports are enabled and which one are disabled. Adaptive This column shows Enable value for all the internal ports which have the Speed&Duplex mode set to auto. For the Master Unit EKOAX IPC-M Confiential 21 of 61...
  • Page 22 Picture. The The private template is only available for the slave. Picture Picture You should click on the Refresh button on the Current Configuration pane In order to get updated information. 22 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 23 WifiBase pane. • Saving Setting: it includes the Saving Setting button which is used by the user to save the current settings to the slave flash memory. Master Unit EKOAX IPC-M Confiential 23 of 61...
  • Page 24 V001 IPCOAX IPC-M User Manual Picture The following table describes the items displayed in this page: 24 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 25 To avoid this problem, use a computer with a wired connection to access the slave. Channel It is the wireless channel used by the slave WiFi interface. The related check box shows the Master Unit EKOAX IPC-M Confiential 25 of 61...
  • Page 26 If you choose WEP encryption method, you need to configure the authentication method and the key. If you choose WiFi Protected Access (WPA-PSK, WPA2-PSK or WPA2/WPA-PSK), you need to configure the algorithm and the key. Table 26 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 27 WAN business with the identifier <n>. • Saving Setting: it includes the Saving Setting button which is used by the user to save the current settings to the slave flash memory. Master Unit EKOAX IPC-M Confiential 27 of 61...
  • Page 28 V001 IPCOAX IPC-M User Manual Picture The following table describes the items displayed in the WAN<n> Setting pane: 28 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 29 7 is the highest priority. Port Binding The check boxes to select the external ports of the slave which are configured with the current WAN business. Table Master Unit EKOAX IPC-M Confiential 29 of 61...
  • Page 30 ISP. The Picture displays the pane shown. To save the changes in the Route Setting panes, you have to click the Apply button and then, to click the Saving Setting button in the Saving Setting pane. 30 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 31 IPCOAX IPC-M User Manual V001 Picture Picture Master Unit EKOAX IPC-M Confiential 31 of 61...
  • Page 32 The shows an example of a router and a bridge connection mode mixed, where LAN3 (STB1) and LAN4 (STB2) are used to connect two IPTV STBs and LAN1, LAN2 and SSID1 are used for internet business. 32 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 33 IPCOAX IPC-M User Manual V001 Picture 2.3.1.6. LAN Configuration This page allows to configure the LAN settings of the slave. The shows this page: Master Unit EKOAX IPC-M Confiential 33 of 61...
  • Page 34 Picture), where the user can add reserved IP addresses which could not be used by the DHCP server to assign it to LAN clients. The changes will be stored when the user clicks the Saving Setting menu. 34 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 35: L2 Switch Configuration

    Saving Setting button is clicked. 2.3.1.8. L2 Switch Configuration This page allows to set the downstream and upstream rate for the LAN, WiFi and WLAN interfaces, as it is shown in the Picture. Master Unit EKOAX IPC-M Confiential 35 of 61...
  • Page 36: Virtual Server Configuration

    The changes will be stored in the slave flash memory when the Saving Setting button is clicked. 2.3.1.10. WiFi Management This page has several panes as it is shown in Picture: 36 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 37: Wifi Upgrade

    Reboot System: click the Reboot button to reboot the WiFi interface. 2.3.1.11. WiFi Upgrade This page allows to configure a FTP server to download a file for upgrading. The Picture shows this page. Master Unit EKOAX IPC-M Confiential 37 of 61...
  • Page 38: Online

    Picture 2.3.2. Online Selecting the Slave→ Online menu, the web interface returns the list of online slaves as it is shown on Picture: Picture For each slave, the following information is displayed: 38 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 39: Template

    The template can then be uploaded to one or more devices thus removing the need to configure the corresponding settings for each device. This menu shows the page displayed in Picture. Master Unit EKOAX IPC-M Confiential 39 of 61...
  • Page 40 Modify: Open a new page to modify the template. See Picture. Check the Template Configuration pane of table Table for more information about all the items displayed in the template modification page. Delete: Delete the selected template. Table 40 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 41: Auto Upgrade

    The system supports up to 253 templates. 2.3.4. Auto Upgrade If you select the SLAVE → Auto Upgrade menu, the page shown in Picture is displayed. Picture This page has 3 panes explained in the following table: Master Unit EKOAX IPC-M Confiential 41 of 61...
  • Page 42 Slave status. PIB & NVM version PIB and NVM file version currently installed on the related slave. Auto Update Enable it shows if the related slave unit has its Auto Update option enabled. 42 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 43: Mac Limit

    If we set the value of Global Mac Limit Parameter to 35 and click the Modify button, all slaves will reboot and the Mac limit for each slave will be set to 35 as it is shown in Picture Master Unit EKOAX IPC-M Confiential...
  • Page 44: Wifi Upgrade

    Mac limit of the slave with ID 1 to 38 as it is shown in Picture 2.3.6. WiFi Upgrade When SLAVE→WiFi Upgrade menu is selected, the page shown in Picture is displayed. 44 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 45: Rf Menu

    The batch upgrade button launches the upgrading process. The Refresh button updates the information shown in the Batch upgrade state list. 2.4. RF Menu The SLAVE→ RF menu shows the page displayed in Picture, Picture Master Unit EKOAX IPC-M Confiential 45 of 61...
  • Page 46 Operation It contains the Modify button to apply the changes done in the configurable parameters of this table. Table The Refresh buttons allow to update the information shown in this page. 46 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 47: Network Menu

    • Error frames • Discarded frames. Click Refresh button to update information. Picture 2.5.2. Config If you select NETWORK→Config menu, the page shown in Picture is displayed. Picture Here you can configure: Master Unit EKOAX IPC-M Confiential 47 of 61...
  • Page 48: Vlan

    If there are several masters placed in the same network, you must set a different SNID for each master in order to avoid the interference among the master units. 2.5.5. Filter The NETWORK→ Filter menu shows the page displayed in Picture. 48 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 49: Igmp

    The IGMP query interval, needed for multicast traffic. Queries can be activate clicking the Active button. • The VLAN used by the IGMP traffic. 2.6. Service Menu The Service menu shows the page displayed in Picture. Master Unit EKOAX IPC-M Confiential 49 of 61...
  • Page 50: System Menu

    2.7. System Menu The system menu provides the access to different menus described in the next sections. 2.7.1. Information The SYSTEM→ Information shows the page displayed in Picture. Picture 50 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 51: Running Status

    ◦ Name of the unit ◦ Contact of the company. ◦ Company location. 2.7.2. Running Status The SYSTEM→ Running Status shows the page displayed in Picture. Picture This page shows two panes: Master Unit EKOAX IPC-M Confiential 51 of 61...
  • Page 52: Slave Type

    The Refresh button updates the information shown in this pane. The Modify button allows to change the values set for these parameters. 2.7.3. Slave Type If you enter in the SYSTEM→SlaveType menu, the Picture is displayed. 52 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 53 IPCOAX IPC-M User Manual V001 Picture This page shows the list of Slave Types available. The following table explains the items displayed in this page. Master Unit EKOAX IPC-M Confiential 53 of 61...
  • Page 54 • Delete: to remove the slave type. Table The New Type button allows to create new slave types. The Picture shows the page displayed to create a new slave type. 54 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 55: Ip Access Control

    Commit button will be clicked. The Back button is used to come back to the IP Access Control page. The Reset button sets the default values for all the parameters shown in the New Certification Rules page. Picture Master Unit EKOAX IPC-M Confiential 55 of 61...
  • Page 56: System Time

    Log Information, shown in the Picture where you can read all the log messages generated by the IPC-M master unit. The Refresh button updates the messages shown. The Clear Log button removes all the current messages. 56 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 57: Account

    The SYSTEM→ Account menu displays the page shown in Picture. This page allows to set a new user name and password to enter in the web management tool. The following table explains the parameters to enter in this page: Master Unit EKOAX IPC-M Confiential 57 of 61...
  • Page 58: Reboot

    Reboot Eoc Chip: it includes the Reboot Eoc Chip button. If this button is clicked the chipset related with the Ethernet over coaxial function is restarted. • Auto Reset EoC Chip: the following table describes the parameters shown in this pane: 58 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 59: Factory

    Table Picture Picture 2.7.9. Factory If you select the SYSTEM→Factory menu, the screen shown in Picture is displayed. Master Unit EKOAX IPC-M Confiential 59 of 61...
  • Page 60: 2.7.10. Upgrade

    Using the FTP server configure in this page, the user can backup the current configuration (clicking the Backup button) and it can also restore a previous configuration backup (clicking the Restore button) which the name set in the File Name parameter. 60 of 61 Confidential Master Unit EKOAX IPC-M...
  • Page 61: Exit Menu

    IPCOAX IPC-M User Manual V001 2.8. Exit Menu Click the EXIT menu to close the web management tool and to return to the login screen ( Picture). Master Unit EKOAX IPC-M Confiential 61 of 61...