PerkinElmer TriNEST Instrument Manual

PerkinElmer TriNEST Instrument Manual

Microplate incubator and shaker

Advertisement

Quick Links

TriNEST
Microplate incubator and shaker
1296-0050 INSTRUMENT MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for PerkinElmer TriNEST

  • Page 1 ™ TriNEST Microplate incubator and shaker 1296-0050 INSTRUMENT MANUAL...
  • Page 3: Table Of Contents

    Contents General information...................1 Changes from previous manual version........................1 Trademarks..................................1 Intended purpose................................1 Contact information............................... 1 Table of symbols................................1 Contents of the package..............................3 Safety information..................4 Conventions..................................4 Warnings and precautions.............................4 General safety..............................4 Chemical and biological hazards........................5 Risks associated with operation and maintenance..................5 Notice regarding serious incidents..........................
  • Page 4 Safety standards................................21 Optional features and spare parts..........................21 Error handling...................24 General..................................24 Error 1, Tmp sens n...............................24 Error 2, Heater n................................24 Error 3, Motor belt................................24 Error 4, Motor rpm............................... 24 WEEE Instructions for PerkinElmer Products.......... 25 Warranty....................26 Index......................27...
  • Page 5: General Information

    TriNEST Microplate incubator and shaker General information General information This manual provides instructions for the installation and use of the TriNEST Microplate incubator and shaker instrument. Changes from previous manual version Changes made to this manual are marked with underlined text.
  • Page 6 TriNEST Microplate incubator and shaker General information Symbol Description Manufacturer Date of manufacture Caution, consult instructions for use (label) Caution, consult instruction for use (instrument) Biological risks Caution, hot surface Consult instructions for use In vitro diagnostic medical device Catalogue number...
  • Page 7: Contents Of The Package

    TriNEST Instrument Manual and CD including translation of the Instrument Manual • Quality Control Certificate The package contains all materials required for the installation and operation of the TriNEST Microplate incubator and shaker. For optional materials and spare parts that can be ordered from PerkinElmer, see Optional features and spare...
  • Page 8: Safety Information

    In cases where a specific hazard or warning has been identified, such as an electrical or burn hazard, the related symbol will replace the standard exclamation mark in warnings. Warnings and precautions This section contains the safety warnings and precautions you need to keep in mind when using the Trinest Microplate incubator and shaker instrument. General safety Warning: This equipment must be installed and used in accordance with the manufacturer's recommendations.
  • Page 9: Chemical And Biological Hazards

    Do not touch the labware with unprotected hands to avoid direct contact with potentially hazardous substances and to prevent any cross contamination of the hardware. If the Trinest instrument becomes contaminated with any sample material; it must be disinfected and cleaned as soon as possible. See Routine maintenance.
  • Page 10 TriNEST Microplate incubator and shaker Safety information it to the manufacturer and to your national authority. The contact information for the manufacturer of this device to report a serious incident is: Wallac Oy Mustionkatu 6, FI-20750 Turku, Finland http://www.perkinelmer.com Phone: +358 2 2678 111...
  • Page 11: Installation And Storage

    TriNEST Microplate incubator and shaker Installation and storage Installation and storage This section contains information regarding the installation and storage of the TriNEST Microplate incubator and shaker instrument. Unpacking Unpack the instrument carefully and check for any damage that may have occurred during transportation. If any parts are damaged or missing, contact your PerkinElmer representative.
  • Page 12 TriNEST Microplate incubator and shaker Installation and storage Figure 3: Two TriNEST instruments stacked on top of each other, back view Make sure the power switch is set to "0" before connecting to the mains.
  • Page 13: Functional Description

    Functional description Functional description This section describes the functionality of the TriNEST Microplate incubator and shaker instrument. Physical description You can use the instrument as a single unit into which up to three microplates of standard size and height (For details, Specifications and features on page 19) can be loaded at a time.
  • Page 14: Control Panel

    TriNEST Microplate incubator and shaker Functional description A plate holder fits into an incubation chamber. It locks into place and holds the plate securely during shaking. It also has a spillage prevention mechanism where it raises the plate against the chamber's ceiling. The plate remains in this position while in the instrument.
  • Page 15: Display

    TriNEST Microplate incubator and shaker Functional description Display The display shows the following symbols (from top to bottom): Program number (01 to 20) and Program name (up to 6 characters) Target incubation temperature in the range of 20 to 70°C.
  • Page 16: Controls

    TriNEST Microplate incubator and shaker Functional description Filled box - plate holder in with plate loaded Full line - plate holder in but empty Dotted line - plate holder out During operation, timers show the incubation time left for each plate. After reaching zero the timers will count up.
  • Page 17 TriNEST Microplate incubator and shaker Functional description Start/Pause button - this will blink when at least one plate has been loaded. Press it to start incubation. It will stop blinking but will remain on. If you press it during incubation, it will begin to blink, the timers will stop and operation will pause.
  • Page 18: Operating Instructions

    TriNEST Microplate incubator and shaker Operating instructions Operating instructions Switch on power with the switch at the back of the instrument. The software and hardware version numbers will briefly appear followed by Program 01. Program selection The current parameter values for Program 01 will be displayed.
  • Page 19: Operation

    TriNEST Microplate incubator and shaker Operating instructions Incubation temperature Incubation time Shake speed Interval shake time Interval rest time Note: The interval times are in minutes and seconds whereas the incubation time is in hours and minutes. Press the Right arrow after the Interval rest time.
  • Page 20: Adding Plates During Operation

    TriNEST Microplate incubator and shaker Operating instructions Warning: Make sure that the incubation temperature is correct when loading the plates and during the incubation. The instrument does not give an error if the actual incubation temperature deviates from the target incubation temperature.
  • Page 21 TriNEST Microplate incubator and shaker Operating instructions Language - only ENGLISH is available. Audible alerts - select ON if you want the instrument to beep when incubation is completed. Select OFF if you do not want it to beep. Show temp - there are three options (see below) Incub - the temperature in the incubation chambers (displayed with a 0.1°C accuracy).
  • Page 22: Routine Maintenance

    You can clean plate holders by removing them from the instrument and wiping with a damp cloth (mild suds). If necessary disinfect with alcohol solution. Any other maintenance should be performed by personnel authorized by PerkinElmer. Please contact your local PerkinElmer representative for organizing the delivery of the instrument for service.
  • Page 23: Specifications And Features

    TriNEST Microplate incubator and shaker Specifications and features Specifications and features This section contains information on the specifications and features of the TriNEST Microplate incubator and shaker instrument. Technical specifications The technical specifications for the TriNEST Microplate incubator and shaker instrument are as follows.
  • Page 24: Time

    One unit: 15.7 kg (34.6 lb) Three stacked units: 47.1 kg (103.8 lb) Environmental conditions The environmental conditions of the TriNEST Microplate incubator and shaker instrument are as follows. Operating temperature Ambient temperature range during operation: 15 - 35°C Humidity...
  • Page 25: Pollution Degree

    • IEC 61326-2-6 Optional features and spare parts The following optional features can be ordered separately from PerkinElmer: • Cooling block: the cooling block is designed to cool the plates once the incubation/shaking is over. The cooling block allows for quicker cooling of the nests. Typically, one cooling block in the middle nest will do but for rapid cooling, place one cooling block in each nest.
  • Page 26 Part number for ordering: 1296-2090 • Plate holder: the TriNEST incubator-shaker unit has three plate holders: one for each of the three chambers. The plate holder not only serves as a drawer to insert the plate into the instrument, it also has a spillage prevention mechanism whereby it raises the plate against the chamber's ceiling where the plate remains while in the instrument.
  • Page 27 TriNEST Microplate incubator and shaker Specifications and features...
  • Page 28: Error Handling

    General Due to the very compact design of the 1296-0050 TriNEST Incubator Shaker it is very limited what is cost efficient to repair on the unit. Therefore the policy is for most failures to fully replace the instrument with a new one.
  • Page 29: Weee Instructions For Perkinelmer Products

    Customer Care Rest of the World: call (+1) 203-925-4602 Products from other manufacturers may also form a part of your PerkinElmer system. These other producers are directly responsible for the collection and processing of their own waste products under the terms of the WEEE Directive.
  • Page 30: Warranty

    Warranty Warranty The enclosed instrument comes with a limited warranty (the “Warranty”) from Wallac Oy (“Wallac”), a PerkinElmer company. This is only a summary of the warranty on the enclosed instrument and shall not be deemed to alter or amend the terms of the Warranty. Consult the terms and conditions, and rental or purchase agreement for a full explanation of the Warranty.
  • Page 31: Index

    Index Transportation Troubleshooting Altitude Unpacking Chemical and biological hazards Contact information Control panel Controls Warnings Conventions WEEE Decommissioning Display Editing parameters Environmental conditions Environmental requirements Installation Instrument description Instrument operation Intended purpose Maintenance Measurements Operating temperature Optional features Optional parts Package contents Pollution Power requirements...
  • Page 34 1296-9160-06 April 27, 2022 Manufacturer: Wallac Oy Mustionkatu 6, FI-20750 Turku, Finland. Tel: 358-2-2678 111. Fax: 358-2-2678 357 www.perkinelmer.com...

Table of Contents