20
electrolux.com.au
CABINET CONSTRUCTION FOR BUILT IN OVEN
900mm
cupboard
door
Oven dimensions
895mm
20mm
20mm
(see NOTE)
100mm
max.
Infill panel
16mm thickness
572mm
552mm

WIRING REQUIREMENTS

For New Zealand Only:
The cooking range must be connected to the supply
by a supply cord fitted with the appropriately rated
plug. This plug is to be compatible with the socket-
outlet fitted to the final sub-circuit in the fixed wiring
that is intended to supply this cooking range.
Supply cord size required:
EVEP916, EFEP916 – 4mm
2
EFEP956 – 10mm
2
EFE914 – 2.5mm
2
Data plate
gives information about rating
is located behind the bottom
of the oven door
A functional switch MUST be provided near
the appliance in an accessible position
(AS/NZS 3000 - Clause 4.7.1).
Wiring MUST be protected against mechanical
failure (AS/NZS 3000 - Clause 3.9).
This cooker requires a means of disconnection
incorporated into the fixed wiring.
The cooker MUST be properly earthed.
This range must be connected with cable of
75°C rating minimum.
This product has passed the insulation resistance test
after manufacture. If the resistance reading is low at
installation, it is probably caused by moisture from the
atmosphere being absorbed by the elements after the
range has been produced. (Pass at 0.01 MΩ AS/NZS
3000 Wiring Rules Clause 8.3.6.2).
Note: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
Rated Power Input
Model
Total kW
A1 kW
A2 kW
EFEP956
15.2
6.0
9.5
IMPORTANT!
Before you cook in your new oven it is important
that the protective oils used in the manufacture
of the product be removed.
Make sure that the room is well ventilated (to allow
smoke to escape).
Run the grill on high for 30 minutes without grill dish.
Then run the oven on 220°C for 1 hour.
Connecting to services and commissioning
This appliance must be installed by an authorised
person, according to all codes and regulations of:
Electrical supply authorities.
Building regulations.
Local government and council authorities.
AS/NZS5601.1 (particular attention to 6.10.1
and figure 6.3, and clause 6.10.1.11).
AS/NZS 3000 (particular attention to clause
4.7.1 and clause 3.9).
Hard wiring detail
1
Remove terminal cover plate from rear panel
of appliance.
2
Fit wires through hole in cover plate and
make connections to terminals.
3
Engage wires into plastic clip. Secure plastic
clip with two long silver screws (supplied in
separate bag).
4
Replace cover plate onto rear panel.
Plastic clips
Plastic clip
Securing points
Electrical connection location - Model EVEP916
113
99
Entry point of electrical cable
21