SECTION 3
SERVICE
Trowel Gearbox Maintenance
Check Oil levels in the gearbox daily (every 8 hours) Add oil if the oil level is below the check sight
glass.
1. To add oil tilt trowel back and remove the fill plug. Add oil through hole opening. Replace fill plug
after proper level has been achieved. DO NOT fill past the fill plug hole opening. Use Kluber GH
6-460 synthetic oil.
2. Each Gearbox has a grease fitting on top cover that must be greased (2 SHOTS ONLY) every 300
operating hours. Use only Mobilith SHC 220 Extended pressure grease. NOTE: On the left side of the
front deck there are grease ports for easy access. Use the two ports on the left, as indicated by the
decal, to grease the right and left hand gearboxes.
TOP COVER
Page 42
Gearbox Maintenance
GEARBOX
SIGHT GLASS
FILL PLUG
GREASE FITTING
Figure 3.1: Gearbox