5. PROGRAMMING
Downloaded from
ManualsNet.com
(2) When using the program enclosed by the dotted line 1) in combination with other remote
device stations, correct the program as shown below.
[System configuration]
[Corrected program]
Note that the master module can register the initialization procedure of only the specified station
out of the multiple remote device stations.
The master module supporting this function is the QJ61BT11N which serial No's first 5 digits is
08032 or later.
Fro details, refer to the CC-Link System Master/Local Module User's Manual, "CHAPTER 4
FUNCTIONS"
*2: Before the communication program is executed with remote device stations, the program
enclosed by the dotted line 1) enables the initial setting by using the SB0D (remote device
station initialization procedure registration instruction) and SB5F (completion status of remote
device station initialization procedure). Initialization processing can't be made only by the
parameter setting of GX Developer.
*3: The program enclosed by the dotted line 2) is necessary only when the initial settings are
changed.
search engine
5-11
MELSEC-A