Pkm BIC7 GK IX 4 Instruction Manual page 66

Built-in oven & hob
Table of Contents

Advertisement

Available languages

Available languages

2.6 Electrical connection of the oven
DANGER!
The appliance must be connected to the mains by a
qualified professional, who is familiar with and adheres to the local
requirements and supplementary regulations of your electricity supplier.
DANGER!
ELECTRIC SHOCK!
I
NSTRUCTIONS FOR THE INSTALLER
❖ Remember that the connection wire should match the connection type and the
power rating of the cooker. The connection wire must be secured in a strain-
relief clamp. The ground wire must be connected to the marked clamp of the
terminal. The electric supply of the appliance must be equipped with an
emergency switch with a distance between the contacts of at least 3 mm which
disconnects the entire appliance from the mains in a case of emergency. Read the
information on the rating label and the connection diagram before connecting
the appliance to the mains.
❖ When the socket is not accessible for the user or a fixed electrical connection
of the appliance is required, an all-pole disconnecting device must be
incorporated during installation. Disconnecting devices are switches with a
contact opening distance of at least 3 mm. These include LS-switches, fuses and
protectors (EN 30335).
➢ H
OW TO OPEN THE CONNECTION BOX
downwards (2) to open the box; s. fig. below. You may need to release two locks
on both sides of the connection box.
Do not carry out the installation yourself. RISK OF
(
QUALIFIED PROFESSIONAL
: move a screwdriver (1) slightly
66
):