Heat & Glo 6000C-IFT Installation Manual page 24

Hide thumbs Also See for 6000C-IFT:
Table of Contents

Advertisement

Top Vent - Horizontal Termination
One Elbow
Note: For corner installations: A 6 inch (152
mm) section of straight pipe may need to
be attached to the appliance before a 90º
elbow, to allow the vent pipe to clear the top
standoffs.
V
Minimum
1
Elbow only
6 in.
1 ft.
1-1/2 ft.
2 ft.
2-1/2 ft.
3 ft.
V
+ H
1
H
ELBOW HEAT SHIELD
(Required when V
Figure 4.10
24
WARNING! Risk of Fire! Elbow heat shield required
when V
must be maintained. See Section 5.A.
6000C-IFT
H
Maximum
1
2 ft
610 mm
152 mm
4 ft.
305 mm
6 ft.
457 mm
10 ft.
610 m
15 ft.
762 mm
20 ft.
914 mm
25 ft.
= 40 ft. (12.2 m) Maximum
1
= 25 ft. (7.6 m) Maximum
1
= 2 ft. or less)
1
Heat & Glo • 6000C-IFT, 8000C-IFT Installation Manual • 2502-980 Rev. M • 3/21
= 2 ft. or less. Clearances to combustibles
1
V
Minimum
1
Elbow Only
1.2 m
1 ft.
1.8 m
2 ft.
3.0 m
3 ft.
4.6 m
4 ft.
6.1 m
V
+ H
1
7.6 m
H
1
8000C-IFT
H
Maximum
1
2 ft.
305 mm
3 ft.
610 mm
6 ft.
914 mm
11 ft.
1.2 m
20 ft.
= 40 ft. (12.2 m) Maximum
1
H
= 20 ft. (6.1 m) Maximum
1
V
1
610 mm
914 mm
1.8 m
3.4 m
6.1 m