Accuracy - Greenlee CM-600 Instruction Manual

Clamp-on meters
Hide thumbs Also See for CM-600:
Table of Contents

Advertisement

Accuracy

Accuracy is specified as follows: (a percentage of the reading + a fixed amount)
at 23 C 5 C (73.4 F 9 F), 0% - 75% relative humidity.
See the Specifications section for operating conditions.
Value
AC Voltage
AC Current
(200 A range)
AC Current
(600 A range)
Resistance*
* Maximum open circuit voltage: 1 V
Continuity
Threshold: Tone sounds if the measured resistance is less than approximately 50 ,
and turns off when greater than approximately 300 .
For the CM-600, AC accuracy is specified for sine waves only.
For the CM-650, accuracy specification applies for waveforms with crest factors less than 2.
• For crest factors from 2 to 3, add 1.4% to accuracy.
• For crest factors from 3 to 4, add 3% to accuracy.
10
Range
0 to 600 V
0 to 199.9 A
0 to 400 A
400 to 600 A
0 to 2000
Accuracy
(1.2% + 3 V)
(1.9% + 0.5 A)
(1.5% + 5 A)
(2.5% + 5 A)
(1.5% + 2
)
Frequency
Range
Impedance
40 to 500 Hz
50/60 Hz
50/60 Hz
50/60 Hz
N/A
Input
2 M
2 nF
N/A
N/A
N/A