Kyocera AD-63 Service Manual page 195

Table of Contents

Advertisement

2FD/2FF/2FG
Code
Contents
C5300
Broken cleaning lamp wire
While the cleaning lamp is on, the bro-
ken cleaning lamp wire detection signal
is detected for 2 s continuously.
C6000
Broken fixing heater wire
• When the power is turned on or at the
start of fixing control from the sleep
mode, 10 s after fixing heater M is
turned on, the detected temperature
of fixing thermistor 2 is lower than 40
°C/104 °F.
• When the power is turned on or at the
start of fixing control from the sleep
mode, 7 s after fixing heater S is
turned on, the detected temperature
of fixing thermistor 1 is lower than 40
°C/104 °F.
• During standby, the detected
temperatures of fixing thermistors 1
and 2 become lower than 60 °C/140
°F.
C6020
Abnormally high fixing unit thermis-
tor temperature
• Fixing thermistor 1 detects
temperature 250 °C/482 °F or higher.
• Fixing thermistor 2 detects
temperature 210 °C/410 °F or higher.
C6050
Abnormally low fixing unit thermis-
tor temperature
• When only fixing heater M is on, fixing
thermistor 2 detects temperature
lower than 80 °C/176 °F during
copying.
• When fixing heater M and fixing
heater S are on, fixing thermistor 2
detects temperature lower than 80 °C/
176 °F or fixing thermistor 1 detects
temperature lower than 100 °C/212 °F
during copying.
1-5-30
Causes
Check procedures/corrective measures
Defective cleaning
Replace the cleaning lamp.
lamp.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
Poor contact in
Check the connection of connector YC10
the fixing unit
on the main PCB and the continuity across
thermistor 1 or 2
the connector terminals. Repair or replace
connector
if necessary.
terminals.
Fixing unit ther-
Check and reinstall if necessary.
mistor 1 or 2
installed
incorrectly.
Fixing unit ther-
Check for continuity. If none, replace the
mostat triggered.
fixing unit thermostat.
Fixing unit heater
Check and reinstall if necessary.
M or S installed
incorrectly.
Broken fixing unit
Check for continuity. If none, replace the
heater M or S
fixing unit heater M or S (see page 1-6-38).
wire.
Measure the resistance. If it is 0 Ω, replace
Shorted fixing unit
thermistor 1 or 2.
the fixing unit thermistor 1 or 2.
Broken fixing unit
Replace the power source PCB.
heater control cir-
cuit on the power
source PCB.
Poor contact in
Check the connection of connector YC10
the fixing unit
on the main PCB and the continuity across
thermistor con-
the connector terminals. Repair or replace
nector terminals.
if necessary.
Measure the resistance. If it is ∞ Ω, replace
Broken fixing unit
thermistor wire.
the fixing unit thermistor.
Fixing unit ther-
Check and reinstall if necessary.
mistor installed
incorrectly.
Fixing unit ther-
Check for continuity. If none, replace the
mostat triggered.
fixing unit thermostat.
Fixing unit heater
Check and reinstall if necessary.
M or S installed
incorrectly.
Broken fixing unit
Check for continuity. If none, replace the
heater M or S
fixing unit heater M or S.
wire.
Remarks
*: Optional