Kyocera AD-63 Service Manual page 192

Table of Contents

Advertisement

Code
Contents
C1110
Paper deck motor 2* problem
• A motor over-current signal is de-
tected continuously for 1 s or longer.
C1120
Deck right lift* position problem
• Deck level switch 2 does not turn on
within 30 s of paper deck motor 2
turning on.
C1130
Deck left lift* position problem
• Deck level switch 1 does not turn on
within 30 s of paper deck motor 1
turning on.
*: Optional
Causes
Check procedures/corrective measures
Paper deck motor
Check the gears and remedy if necessary.
2 does not rotate
correctly (the mo-
tor is overloaded).
Paper deck motor
Reinsert the connector. Also check for con-
2 connector
tinuity within the connector cable. If none,
makes poor con-
repair or replace the cable.
tact.
Defective deck
Check if CN5-4 on the desk main PCB
level switch 2.
goes low when desk level switch 2 is
turned off. If not, replace desk level switch
2.
Poor contact of
Reinsert the connector. Also check for con-
deck level switch
tinuity within the connector cable. If none,
2 connector termi-
repair or replace the cable.
nals.
Defective paper
Check for continuity across the coil. If
deck motor 2.
none, replace paper desk motor 2.
Poor contact of
Reinsert the connector. Also check for con-
paper deck motor
tinuity within the connector cable. If none,
2 connector termi-
repair or replace the cable.
nals.
The deck right lift
Check the gears and belts, and remedy if
does not rise
necessary.
properly.
Defective deck
Check if CN5-7 on the desk main PCB
level switch 1.
goes low when desk level switch 1 is
turned off. If not, replace desk level switch
1.
Poor contact of
Reinsert the connector. Also check for con-
deck level switch
tinuity within the connector cable. If none,
1 connector termi-
repair or replace the cable.
nals.
Defective paper
Check for continuity across the coil. If
deck motor 1.
none, replace paper desk motor 1.
Poor contact of
Reinsert the connector. Also check for con-
paper deck motor
tinuity within the connector cable. If none,
1 connector termi-
repair or replace the cable.
nals.
The deck left lift
Check the gears and belts, and remedy if
does not rise
necessary.
properly.
2FD/2FF/2FG