Communication Board; Primary Unit Communication Board - SolarEdge SE8K-N4 Installation Manual

Three phase inverter with synergy technology
Table of Contents

Advertisement

Communication Board

The communication board is in the Primary Unit with an extension in the Connection Unit.

Primary Unit Communication Board

Open the Primary Unit   c over to access the communication board to: 
 
GSM- connect a GSM modem. See Communication Options on page 55.
l
 
RS485-1 - connected to the Connection Unit communication board. For connecting  
l
multiple inverters over the same bus, connect RS485 wires to the terminal blocks   o n 
the Connection Unit Communication Board. For more information see, Connection 
Unit Communication Board  on page 58
 
RS485-2 - connect   a  non-SolarEdge device,   s uch as a meter or a third party data logger, to the RS485-2 
l
connector. Every pair of in and out wires are connected to the same pin.
 
Power Reduction Interface (PRI) - connect     a
l
control_configuration.pdf
 
Three Phase Inverter with synergy technology Guide MAN-01-00402-1.1
 power reduction device. See application_note_power_
Figure 27: Primary Unit communication board
Chapter 6: Setting Up Communication
57

Advertisement