Stage An Nounce /Re Lay Con Tacts - Telex RadioCom BTR-800-H1 Operating Instructions Manual

Professional wireless intercom system
Table of Contents

Advertisement

BTR-800
RECEIVE
FCC ID: B5DM514
CANADA 1321231218A
TRANSMIT
BASE STATION
POWER
LINK
I/C
HIGH
NORM
RTS
ON
OFF
TELEX
CLEARCOM
STAGE ANNOUNCE RELAY
Stage An nounce / Re lay Con tacts
The stage an nounce out put con nec tor is where au dio ex its the
base when any of the beltpacks press the [SA] but ton. The
out put is bal anced au dio though a male 3-pin XLR. The stage
an nounce out put level is set at the fac tory for 2 Vrms typ i cal
out put at rated de vi a tion into 600 Ohms. This should be ad e - -
quate for most ap pli ca tions. There is an in ter nal level ad just - -
ment for this out put too. See Fig ure 26 for the lo ca tion of the
small level trim mer. The top cover of the base sta tion must be
re moved for ac cess.
Re lay Out put Schematic
PHOENIX
TYPE
CONNECTOR
Re lay Con tact Jack Adapter
(Screw Ter mi nal Adapter)
INTERCOM A
2 WIRE
PUSH
L
O
4 WIRE
O
RELAY
P
CONTACT
T
H
R
U
Base Sta tion - Rear Panel
PIN 1
PIN 2
Fig ure 24
Fig ure 25
AUXILIARY
INTERFACE
INTERCOM B
AUXILIARY AUDIO
2 WIRE
PUSH
PUSH
L
O
4 WIRE
O
P
T
H
R
U
INPUT
OUTPUT
A re lay con tact clo sure is also ac ti vated when a beltpack user
presses the [SA] but ton. The con tacts are nor mal open (N.O.).
Rat ing: 1 Amp at 24 volts AC/DC max i mum. A "Phoe nix"
type con nec tor (sup plied) plugs into the re lay con tact port on
the rear of the base sta tion. This con nec tor pro vides a
screw-type clo sure for an easy con nec tion to wires.
In ter nal Stage An nounce Level Con trol
5-10
100-240 VAC 50-60 Hz
STAGE ANNOUNCE
Telex
Telex Communications, Inc.
OUTPUT
POWER
STAGE ANNOUNCE
STAGE ANNOUNCE
LEVEL CONTROL
U21
VR4
BACK
FRONT
Fig ure 26
TRANSMIT
MADE IN USA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Radiocom tr-800Radiocom tr-825Radiocom btr-800

Table of Contents