TR-800 Menu Struc ture

ClearScan™

ClearScan
per forms a fre quency scan of the fac tory-defined
TM
and any set-up user-programmable groups in or der to find the
clear est group. Af ter about 30 sec onds, the clear est group is
dis played. A group is de fined by re ceive 1 and 2 fre quen cies.
The next best group and so forth may be ac cessed with the
[DOWN] and [UP] ar row but tons.
Press and hold [MENU] + [SET] for three sec onds to en -
ter ClearScan
. The beltpack will now start search ing for
TM
the clear est groups. The group sym bol will flash in di cat -
ing the beltpack is scan ning for clear groups.
ClearScan
will scan all groups. It will then dis play the
TM
1st group it came to that had the clear est re ceive chan nels.
The [UP] / [DOWN] but tons may be used to se lect the
next best group and so forth. Hit [SET] to place the
beltpack on this group and re turn to the group/chan nel
screen.