Napoleon Prestige PRO BIPRO825RBIP-3 Manual page 24

Table of Contents

Advertisement

Available languages

Available languages

24
BIPRO825 BUILT-IN INSTRUCTIONS
EN
1
!
WARNING!
death.
The grills electrical systems are pre assembled in an electrical box which must be mounted a minimum
of 4" (102 mm) below the bottom of the grill as illustrated. Fasten the electrical box to the inside of the
enclosure, making sure the ventilation holes are not obstructed.
Plug the power supply into a Ground Fault Interrupter (GFI) protected circuit. Never remove the the
grounding plug or use with an adapter of 2 prongs.
www.napoleongrills.com
N415-0543 DEC 12.18.indd 24
GFI Outlet
8" (203mm)
maximum
(178mm)
LOCATED INSIDE CABINET
Failure to follow these instructions could result in property damage, personal injury or
4" (102mm) minimum, bottom
of the grill to top of the electrical
panel.
9⅝"
(244mm)
7"
x2
2
x1
N415-0543 DEC 12.18
12/13/2018 10:19:31 AM