www.ti.com
3.4
Connecting to the USB
With the PC turned on, connect the USB cable from the PC to the TSW1100 USB connector, J10. At this
point, the PC should recognize the TSW1100. To verify, go to the Hardware Device Manager, select USB
Device, and ensure the TSW1100 is listed as a USB device. At this point, LED D13 lights on the
TSW1100, signaling that the device has been configured properly and is communicating with the PC. This
should be the only lighted LED. If at this point more than D13 is lighted, depress the reset switch, SW2, on
the TSW1100.
3.5
Launching the TSW1100 Software
With the TSW1100 recognized by the hardware device manager, the software package can be run. To run
the program, click on Start → Program Files → Texas Instruments → TI ADC Capture Card.
3.6
Using the TSW1100 Software
Using the TI chip selector, select the ADS5231/32. The software then configures itself for operation with
the ADS5231/32 EVM. Fill in the appropriate fields describing the hardware setup conditions. When
finished, acquire data by clicking on the red circular Acquire Data button.
4
Physical Description
This chapter describes the physical characteristics of the PCB, providing the layout of each board layer.
SBAU111A – May 2006 – Revised June 2007
Submit Documentation Feedback
Physical Description
ADS5231/32 EVM
9