appenDICes
lamp replacing proceduree:
1.
Switch off the power to the projector by pressing the Power button.
2.
Allow the projector to cool down at least 30 minutes.
3.
Disconnect the power cord.
4.
Remove two screws on the lamp compartment cover.
5.
Remove the lamp compartment cover.
6.
Disconnect the lamp connector.
7.
Remove the two screws from the lamp module. Lift the module handle up.
8.
Pull firmly on the module handle to remove the lamp module.
To replace the lamp module, reverse the previous steps. While installing, align the lamp module with the
connector and ensure it is level to avoid damage.
9.
Turn on the projector and do "Lamp Reset" after the lamp module is replaced.
Lamp Reset: (i)Press "Menu" -> (ii)Select "Setup" -> (iii)Select "Lamp Settings" -> (iv)Select "Lamp
Reset" -> (v)Select "Yes".
Warning: Lamp Connector must be installed flush with the connector base as shown in the image below.
A gap between the Lamp Connector and the connector base will cause damage to the projector. The following
images illustrate correct and incorrect Lamp Connector installations.