Supermicro Supero SUPERSERVER 6027TR-DTRF User Manual page 86

Table of Contents

Advertisement

SUPERSERVER 6027TR-DTQRF/DTFRF/DTRF User's Manual
Changing a System Fan
1. If necessary, open the chassis while the power is running to determine which
fan has failed. (Never run the server for an extended period of time with the
chassis cover open.)
2. Remove the failed fan's power cord from the backplane.
3. Lift the fan housing up and out of the chassis.
4. Push the fan up from the bottom and out of the top of the housing.
5. Place the replacement fan into the vacant space in the housing while making
sure the arrows on the top of the fan (indicating air direction) point in the
same direction as the arrows on the other fans.
6. Put the fan back into the chassis and reconnect the cable (see Figure 6-4
and Figure 6-5 for details).
7. Confi rm that the fan is working properly before replacing the chassis cover.
Figure 6-4. System Fan Placement
6-6

Advertisement

Table of Contents
loading

Table of Contents