Baileigh Industrial CS-225M-V2 Operator's Manual page 20

Manual cold saw
Table of Contents

Advertisement

7. Attach the feed handle to the head assembly.
8. Insert the threaded end of the feed handle (L) into
the gear oil fill hole (M).
9. Turn the handle clockwise (cw) until tight so that
the trigger switch (N) points up.
10. Tighten jam nut clockwise (cw).
11. Connect feed handle cable to motor box.
12. Route the feed handle cable over the transfer case
to the back of the electrical.
13. Plug the feed handle cable connector (O) into the
open socket.
14. Tighten the connector nut.
15. Attach the bar stop to the vise.
16. Loosen the clamping screw (P) to allow the bar stop to
slide on the extension rod and allow clearance to turn
the rod tight.
17. Insert the threaded end of the bar stop extension rod (Q)
into the mounting block on the right side of the machine
base. Turn cw until tight fully seated and tight.
18. Attach the return springs.
19. Raise the head assembly to the full up position and hold
place.
20. Remove the cap screw (R) from head casting. Swing the
spring into position and install that cap screw to secure
in place.
21. Tighten the cap screw only about half of the thread
length. DO NOT over tighten and pinch or bind the
spring.
22. Repeat the steps for the remaining spring.
R
17
17
N
L
M
O
Q
P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-225m1013715

Table of Contents