General Information; Electrical Requirements - Viking Range VRI7240 Installation Manual

Hide thumbs Also See for VRI7240:
Table of Contents

Advertisement

General Information

Area Requirements
Verify the following:
• Unit can fi t into residence and can be moved around corners and
through doorways.
• Floors can support unit's weight plus food weight (approximately
1200 pounds [540 kg] per unit).
• Floors underneath refrigerator are level with surrounding fi nished
fl oor.
• Remove anything attached to rear or side walls that can obstruct
unit installation.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
• Water line is in correct location.
DO NOT
install a refrigeration unit near a heat source, nor in a
location where the surrounding temperature will fall below
60º F (16º C).
• Keep ventilation openings clear of obstructions.

Electrical Requirements

It is the customer's responsibility to:
• Contact a qualifi ed electrical installer.
• Assure that the electrical installation is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or Canadian Electrical Code C22.1-1998 and
C22.2 No. 0-M91 (or latest edition), and all local codes and
ordinances.
A 115 volt, 60-Hz, 15 amp, fused, electrical supply is required. It
is required that a separate circuit serving only this appliance be
provided. In a dual installation, each appliance must have a separate
115 volt, 60-Hz, 15 amp, fused, electrical supply. This appliance is
equipped with a power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the cord must be plugged
into a mating 3-prong, grounding-type wall receptacle.
If the supply cord is damaged, it must be replaced by the
manufacturer or it service agent or a qualifi ed service technician in
order to avoid a hazard.
DO NOT
use an extension cord or ungrounded (two-prong)
adapter.
If codes permit a separate grounding wire
to be used, it is recommended that a qualifi ed electrician determine
that the grounding path is adequate.
DO NOT
ground to a gas line. Check with a qualifi ed electrician if
you are not sure if theappliance is properly grounded.
have a fuse in the neutral or grounding circuit.
Anti-Tip Requirements
The anti-tip device should be installed prior to moving the unit into
place.
To avoid serious illness or death, connect to a potable
water supply only. DO NOT use unit where water
is microbiologically unsafe or of unknown quality,
without adequate disinfection before or after the
system. Systems certifi ed for cyst reduction may be
used on disinfected water that may contain fi lterable
cysts. The contaminants or other substances removed
or reduced by this water treatment system are not
necessarily in your water.
Be sure to have a replacement cartridge available when
fi lter change is required.
• If water fi ltration system has been allowed to freeze,
replace fi lter cartridge.
• If system has not been used in several months, and
water has an unpleasant taste or odor, fl ush system by
dispensing 2-3 glasses of water. If unpleasant taste or
odor persists, change fi lter cartridge.
• Make sure to tighten the water fi lter to its home position.
An improper tightened water fi lter will not allow the
water to fl ow.
Use only 1/4" (6 mm) copper tubing for water line. DO
NOT install copper tubing in area where temperatures
drop below 35º F (1.7º C). Before attaching copper tubing
to the unit, fl ush at least 2 quarts (1.9 L) of water through
the copper tubing and into a bucket to remove any
particles in the water line.
Viking Range, LLC is not responsible for property
damage due to improper installation or water
connection.
DO NOT
13
Water Supply Requirements
WARNING
CAUTION

Advertisement

Table of Contents
loading

Table of Contents