4.5.2 Clear fault memory

After reading the retrieved codes from the vehicle and certain repairs have been
carried out, you can use this function to erase the codes from the vehicle. Before
performing this function, please be sure the vehicle's ignition key is in the ON
position with the engine off.
Tap "Clear fault memory" in function menu, the system will automatically delete
the currently existing trouble code.
Note: The trouble code will not disappear until the trouble was completely cleared.

4.5.3 Read data stream

This option retrieves and displays live data and parameters from the vehicle's ECU.
Tap "Read Data Stream" in function menu, the system will display data stream
items.
Fig. 4-18
On-screen Buttons:
Select Page: Tap it to select all items of the current page.