Pepperl+Fuchs SI00113O-F Instruction Manual

Pepperl+Fuchs SI00113O-F Instruction Manual

Vibration limit switch

Advertisement

Quick Links

Betriebsanleitung
Instruction Manual
Manuel d'instructions
Vibration Limit Switch
Vibracon LVL-M2C
ATEX:
II 1/2G Ex ia IIC T6...T3 Ga/Gb
IECEx:
Ex ia IIC T6...T3 Ga/Gb
SI00113O-F/98/A3/15.16
71300097
SI00113O-F
DE – Sicherheitshinweise für elektrische Betriebsmittel für
explosionsgefährdete Bereiche, siehe Seite 5
EN – Safety instructions for electrical apparatus for explosion-
hazardous areas, see page 13
FR – Conseils de sécurité pour matériels électriques destinés aux
zones explosibles, regardez à la page 21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SI00113O-F and is the answer not in the manual?

Questions and answers

Summary of Contents for Pepperl+Fuchs SI00113O-F

  • Page 1 ATEX: II 1/2G Ex ia IIC T6...T3 Ga/Gb IECEx: Ex ia IIC T6...T3 Ga/Gb SI00113O-F DE – Sicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche, siehe Seite 5 EN – Safety instructions for electrical apparatus for explosion- hazardous areas, see page 13 FR –...
  • Page 2 Declaración UE de conformidad oświadcza, że produkt ten jest zgodny z obowiązującą Europejską Dyrektywą. Por la presente declaración y la inclusión de la marca CE, el fabricante Pepperl+Fuchs, Zastosowane wytyczne, normy oraz dukumenty podane są w deklaracji zgodności. declara que el producto cumple con las directivas europeas pertinentes. Las directivas, normas y documentos de aplicación se indican en la declaración de conformidad.
  • Page 3 Notified Body QM-System / Notifizierte Stelle des QM-Systems: Physikalisch Technische Bundesanstalt (0102) We, Pepperl+Fuchs GmbH declare under our sole responsibility that the Bundesallee 100 products listed below are in conformity with the listed European Direc- 38116 Braunschweig tives and standards.
  • Page 4 Vibracon LVL-M2C SI00113O-F ANNEX TYPE CODE can be replaced by the following code: Schlüssel ersetzt werden: LVL-MX-XXXXX-XXXXXX-XX LVL-MX- Product Process Probe version, Length Housing Electrical output Additional option Certificate Family Connection A1, A2, A3, A4, A5, AC, WA E2, EB, E1,EA...
  • Page 5: Table Of Contents

    Vibracon LVL-M2C SI00113O-F Vibration Limit Switch Vibracon LVL-M2C Table of Contents Associated documentation ............
  • Page 6: Associated Documentation

    Vibracon LVL-M2C SI00113O-F Associated This document is an integral part of the following documents: KA00162O documentation The documents which are supplied and correspond to the device type apply. Supplementary Explosion protection compendium documentation Manufacturer's EU-Declaration of conformity certificates see page 3...
  • Page 7: Safety Instructions: General

    • Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and/or transmitter, depending on the range of application, and the temperature class. • Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Pepperl+Fuchs.
  • Page 8: Safety Instructions: Special Conditions

    Vibracon LVL-M2C SI00113O-F Safety instructions: Permitted ambient temperature range at the electronics housing: Observe the information in the Special conditions temperature tables. • In the event of additional or alternative special varnishing on the housing or other metal parts: – Observe the danger of electrostatic charging and discharge.
  • Page 9 Vibracon LVL-M2C SI00113O-F Basic specification, feature electrical connection, option PA – – Figure 2 Zone 1 Tank; Zone 0 Electronic insert Housing Permitted terminating resistor Ex ia IIC Certified associated apparatus Power supply Tank; Zone 1 Potential equalization • Connect the device using suitable cable and wire entries of protection type ”Intrinsic safety (Ex i)".
  • Page 10: Safety Instructions: Zone 0

    Vibracon LVL-M2C SI00113O-F Basic specification, feature electrical connection, option PA Figure 3 Version 1 Use small capacitors (e. g. 1 nF, 1500 V, dielectric strength, ceramic). Total capacitance connected to the screen may not exceed 10 nF. Version 2 Terminating resistor...
  • Page 11: Temperature Tables

    Vibracon LVL-M2C SI00113O-F Temperature tables The dependency of the ambient and process temperatures upon the temperature class: Temperature class Process temperature T (process): Ambient temperature T (ambient): Sensor Electronics -50 °C to +80 °C -50 °C to +70 °C -50 °C to +95 °C -50 °C to +70 °C...
  • Page 12: Connection Data

    Vibracon LVL-M2C SI00113O-F Connection data Connection to power supply Basic specification, feature electrical connection, options SI, N1, N2 • Associated intrinsically safe power supply unit with max. electrical specifications below the characteristic values of the electronic inserts Electrical connection Electronic insert...
  • Page 13 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the "Elektrotechnik und Elektroindustrie (ZVEI) e.V." including the supplementary clause: "Erweiterter Eigentumsvorbehalt".
  • Page 14 PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 71300097 68307 Mannheim · Germany Tel. +49 621 776-0 SI00113O-F/98/A3/15.16 E-mail: info@de.pepperl-fuchs.com FM7.2 For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/pfcontact www.pepperl-fuchs.com DOCT-0560B 115139 Subject to modifications 10/2018 Copyright Pepperl+Fuchs • Printed in Germany...

This manual is also suitable for:

Vibracon lvl-m2c

Table of Contents