9.2 Measurement Specifications

The following table provides specifications for the measured parameters.
Measurement
Indoor Temperature
Outdoor Temperature
Indoor Humidity
Outdoor Humidity
Barometric Pressure:

9.3 Power Consumption

Base station (display console) : 4 x AA 1.5V Alkaline or Lithium batteries (not included)
Remote sensor : 2 x AAA 1.5V Alkaline or Lithium batteries (not included)
Battery life: Minimum 12 months for base station with one sensor and excellent reception.
Intermittent reception and multiple sensors may reduce the battery life.
Minimum 12 months for thermometer-hygrometer sensor (use lithium batteries in cold
weather climates less than -4 °F)

10 Troubleshooting Guide

Problem
Wireless remote (thermo-hygrometer) not
reporting in to console.
There are dashes (--.-) on the display
console.
Version 1.0
©Copyright 2014, Ambient LLC. All Rights Reserved.
Range
32 to 140 °F
-40 to 140 °F
10 to 99 %
10 to 99%
8.85 to 32.50 inHg
Solution
If any of the sensor communication is lost, dashes (--.-)
will be displayed on the screen. To reacquire the signal,
press and hold the CHANNEL/+ button for 3 seconds,
and the remote search icon
displayed. Once the signal is reacquired, the remote
search icon
will be displayed.
The maximum line of sight communication range is 300
feet and 100 feet under most conditions. Move the sensor
assembly closer to the display console.
If the sensor assembly is too close (less than 5'), move
the sensor assembly away from the display console.
Accuracy
± 1 °F
± 1 °F
± 5% (only guaranteed
between 20 to 90%)
± 5% (only guaranteed
between 20 to 90%)
± 0.08 inHg
will turn off, and the current values
Resolution
0.1 °F
0.1 °F
1 %
1 %
0.01 inHg
will be constantly