Caravan & motor home sealed lithium battery photoelectric smoke alarm with hush

Advertisement

Operation
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH
CONTROL FEATURE.
CAUTION: BEFORE USING THE ALARM HUSH FEA-
!
TURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE
CERTAIN A SAFE CONDITION EXISTS.
FLASHING LED LIGHT: This smoke alarm is equipped with a
flashing red indicator light with the following modes of
operation:
• The LED will flash every every 60-70 seconds in the stand-
by mode signifying that the alarm is receiving power.
• The LED will flash every 0.5 seconds when the alarm is
sounding. The flashing LED and pulsating alarm will
continue until the air is cleared.
• The LED will flash every 10 seconds while in Hush mode.
• The LED will flash twice every 30 seconds when the alarm
is within 30 days of low battery.
• The LED will flash every 30 seconds (with a chirp every 60
seconds) when the alarm is in low battery. (replace alarm
immediately)
• The alarm will chirp every 30 seconds without an LED flash
to indicate a fault condition with the processor of the alarm.
• The LED will flash every 30 seconds with 2 chirps when the
alarm has exceeded its life (replace alarm).
If your alarm regularly nuisance alarms (see "Nuisance
Alarms") when cooking, this indicates the alarm may be
mounted too close to the source e.g. cooking area.
However, by pressing the Hush button prior to cooking,
you can densisitise the alarm for approximately
10 minutes.