Electric energy meter, 3-phase

Advertisement

Quick Links

LE-03d
Electric energy meter,
3-phase
Do not dispose of this device in the trash along with other waste!
According to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collec� on, as well as to store the occasion of
the purchase of new equipment (in accordance with the principle of old-for-new, regard-
less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the
environment and human health.
Compliance
Directive MID
Certificate number
Purpose
The LE-03d is a static (electronic) calibrated electricity meter of
three-phase alternating current in a semidirect system.
Functioning
A special electronic system under the influence of flowing cu-
rrent and applied voltage in each phase generates pulses pro-
portional to the energy drawn in the respective phase. Energy
consumption in the phase is indicated by a flashing of correspon-
ding LED (A, B, C). The sum of the three phase pulses is indicated
by a flashing LED and converted into energy absorbed througho-
ut the three-phase system. Its value is displayed by the segment
LCD display.
The fractional digit represent the decimal (.1 kWh = 100 Wh).
F&F Filipowski sp. j.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
2014/32/EU
0120/SGS0119
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for F&F LE-03d

  • Page 1 2014/32/EU Certificate number 0120/SGS0119 Purpose The LE-03d is a static (electronic) calibrated electricity meter of three-phase alternating current in a semidirect system. Functioning A special electronic system under the influence of flowing cu- rrent and applied voltage in each phase generates pulses pro- portional to the energy drawn in the respective phase.
  • Page 2: Measured Value

    Measured value Active energy consumed [kWh] Pulse output The indicator has a pulse output. This allows you to connect a pulse meter-reading pulses generated by the counter. For proper operation of the indicator is not required to connect additional devices. Sealing The meter has sealable input and output terminal covers to pre- vent any attempts to bypass the meter.
  • Page 3: Front Description

    Meter number The meter is marked with individual serial number allowing its unambiguous identification. The marking is laser engraved and cannot be removed). Front description - 3 -...
  • Page 4 Dimensions Mounting 1. Disconnect the power supply. 2. The indicator mounted on a rail in the distribution box. 3. Connect the power in accordance with the markings to the terminals 1 (L1), 3 (L2), 5 (L3). 4. Connect the measured circuit or a single receiver to the termi- nals in accordance with the markings to the terminals 2 (L1), 4 (L2), 6 (L3).
  • Page 5: Wiring Diagram

    Wiring diagram power input L1 power output L1 power input L2 power output L2 power input L3 power output L3 neutral N-wire pulse output (–) pulse output (+) - 5 -...
  • Page 6 Technical data installation 4-wire rated voltage 3×230/400 V minimum measured current 0.04 A base current 3×10 A maximum current 3×100 A voltage measuring range 160÷265 V measurement accuracy (EN50470-1/3) B class rated frequency 50 Hz insulation protection class housing PC+ABS material own power consumption <10 VA;...
  • Page 7: Warranty

    Warranty F&F products are covered by a 24-month warranty from the date of purchase. The warranty is only valid with proof of purchase. Contact your dealer or contact us directly. CE declaration F&F Filipowski sp. j. declares that the device is in conformity with the essential requirements of The Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE.
  • Page 8 General work safety conditions » Please read the instructions carefully before installation. » The device should be installed and operated by qualified per- sonnel who are familiar with its design, operation, and asso- ciated risks. » Do not install a meter that is damaged or incomplete. »...

Table of Contents