26. Reconnect the oil return and auto top off flexlines to the frypot, and replace aluminum tape, if
necessary, to secure heater strips to the flexlines.
27. Insert the high-limit thermostat leads disconnected in step 18 (see illustration on page 1-3 for pin
positions).
28. Reconnect the auto top-off sensors.
29. Reconnect the drain safety switch wiring to the switch(es) in accordance with the diagram below
then reinstall the switch covers.
30. Reinstall the drain tube assembly.
31. Reinstall the top connecting strips, top cap, tilt housing, back panels and contactor plug guards.
32. Reinstall controllers in the control panel frame and reconnect the wiring harnesses and ground
wires.
33. Reposition the fryer under the exhaust hood and reconnect it to the electrical power supply.

1.9 Built-in Filtration System Service Procedures

1.9.1 Filtration System Problem Resolution

One of the most common causes of filtration problems is placing the filter paper on the bottom of the
filter pan rather than over the filter screen.
Ensure that filter screen is in place prior to filter paper placement and filter pump
operation.
Improper screen placement is the primary cause of filtration system
malfunction.
Whenever the complaint is "the pump is running, but no oil is being filtered," check the installation of
the filter paper, and ensure that the correct size is being used. While you are checking the filter paper,
verify that the O-rings on the pick-up tube of the filter pan are in good condition. A missing or worn
O-ring allows the pump to take in air and decrease its efficiency.
If the pump motor overheats, the thermal overload will trip and the motor will not start until it is reset.
If the pump motor does not start, press the red reset switch (button) located on the rear of the motor.
If the pump starts after resetting the thermal overload switch, then something is causing the motor to
overheat. A major cause of overheating is when several frypots are filtered sequentially, overheating
the pump and motor. Allow the pump motor to cool at least 30 minutes before resuming operation.
Pump overheating can be caused by:
CAUTION
1-9