Fantasea Line FA6500 V2 Instruction Manual page 45

For sony a6300 and a6500
Table of Contents

Advertisement

Vacuum Valve Removal
1. In case of removing the Vacuum Valve for whatever reason,
follow the steps below:
a. Remove the Vacuum Valve from its port using the
wrench. Fit the wrench around the edges of the
Vacuum Valve base and turn it counterclockwise until
the valve has been completely unscrewed.
b. Install the M16 Cap included in the package on the
Vacuum Valve port by screwing it all the way in
(image #62).
Important Notices
1. Once the Vacuum Valve has been removed and an M16 port cap has been
installed on the port, it important to carry out the first dive with the housing
empty (no camera installed inside) in order to verify that the housing
watertight seal has not been affected during the replacement.
2. The Vacuum Valve port was designed to accommodate the Vacuum Valve
only and any other components should not be installed on this port. For
installation of electronic strobe triggering bulkheads, HDMI connectors or
any other accessories, use the standard M16 Port found at the top left
corner of the housing.
Image #62
FA6500 V2 Housing Instruction Manual 20190402
45