12. To extend the battery's lifespan:
a. Avoid draining the battery all the way to 0%. Even though the unit can handle a few more
dives even when the LED Indicator starts rapidly flashing blue, it is best to connect the
unit to a charger at this point.
b. During long periods of storage, the unit should be stored partially charged in a cool and
dry area.
Performing a Pre-Dive Check
1. Prior to closing the housing, turn the unit on using the power switch on the Signal Board. The
switch should be pushed leftwards in order for the unit to be turned on. Make sure the unit is
properly charged and that the LED indicator flashes slowly (approx. 1 flash per second).
2. Lock the housing, lens port and all other accessories which their installation might have an effect
on the watertight seal of the housing. Camera should be turned off prior to the pre-dive check.
Important Notice
3. Remove the protective cap from the Vacuum Valve by gently turning it counterclockwise and
screwing it out (image #56). Make sure you're only removing the protective cap when turning it,
rather than the complete valve. If the valve screws out together with its cap, use the wrench
included in order to tighten the valve inside the port. This will allow for easy and safe removal of
the protective cap when screwed out.
Image #56
The housing should be completely set up for the dive prior to performing the
vacuum pre-dive check. Any modifications carried out on the housing after the
pre-dive test has been completed necessarily turn the check results irrelevant
and require performing an additional pre-dive check.