TECHNICAL SPECIFICATIONS

Model
Elements
Length (cm)
Width (cm)
Height (cm)
Weight (kg)
Voltage
Isolation
Power (W)
Electronic Control
All models are equipped with control function trough G-Control Hub connected to the network.

PRODUCT FICHE

MODEL(S): GABARRON RD4W, RD6W, RD8W, RD10W, RD12W, RD14W
Item
Heat Output
Nominal heat output
Minimum heat output
Maximum continuous heat
output
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
In standby mode
Type of heat output / room temperature control
Electronic room temperature control plus week timer
Other control options
Room temperature control, with open window detection
With distance control option
With adaptive start control
Contact details
Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric fixed local space heater.
RD4W
RD6W
4
42
58
9
12
500
750
Triac
Triac
Symbol
RD4W
P
0.5
nom
P
N.A.
min
P
0.5
max,c
0.000
el
max
0.000
el
min
el
<0.0005
SB
Item
ELNUR, S.A.
Travesía de Villa Esther, 11
28110 – Algete (Madrid), Spain
RD8W
6
8
74
8 cm plus 2 cm clearance
58
15
220 – 240 V~
Clase I /Class I
1000
Triac
Value
RD6W
RD8W
0.75
1.0
N.A.
N.A.
0.75
1.0
0.000
0.000
0.000
0.000
<0.0005
<0.0005
19
RD10W
RD12W
10
12
90
106
18
21
1250
1500
Triac
Triac
RD10W RD12W RD14W
1.25
1.5
N.A.
N.A.
N.A.
1.25
1.5
0.000
0.000
0.000
0.000
0.000
0.000
<0.0005
<0.0005
<0.0005
RD14W
14
122
24.5
2000
Relay
ErP
Unit
2.0
kW
kW
2.0
kW
kW
kW
kW
Value. All
models
Yes
Yes
Yes
Yes

Advertisement