Download Print this page

Operation; Maintenance; Specifications - Gabarron TGV200 Operating Instructions Manual

Ceramic fan heater

Advertisement

Available languages

Available languages

Holes used to hang the
product on the wall

3.- OPERATION

WARNING : Always choose a safe location for the heater, keeping in mind the safety instructions outlined in point 1.
1.
Power indicator light
2.
Thermostat knob
3.
Power selector
4.
Air outlet
Before using the heater make sure that it is on a flat and stable surface. Damage may occur if it is placed on an incline or decline.
Turn off all the controls of the heater, and then plug the heater power plug directly into a standard AC outlet. Be sure plug fits tightly into
outlet.
Rotate the thermostat regulator (2) clockwise to the position MAX, then rotate the power selector (3) from 0 (OFF) to
the wind-motor, and check if it acts normally.
Rotate the power selector (3) from
(LOW) for 1000W
(HIGH) for 2000W.
When the desired temperature is reached, rotate the thermostat regulator (2) counter clockwise until the pilot light (1) goes off. The desired
temperature will be kept constant by the thermostat.

4.- MAINTENANCE

Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.
Do not use solvents or abrasive products for cleaning.
Do not immerse the heater in water.
Do not allow the interior to get wet as this could create a hazard.
In case of malfunction or doubt, do not try to repair the heater yourself; it may result in a fire hazard or electric shock.
This thermal radiator has been manufactured under an assured quality system using environment friendly processes.
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way.

5.- SPECIFICATIONS

Model:
TGV200
Voltage: 230V~
Input:
2000W
Class II
IP23
Net weight: 2kg
Note: Please make sure the screw fixed in the hole tightly and the heater hanged on the wall firmly.
WARNING: When you install your appliance in fixed position, you may cut the plug and connect the
three conductors of the supply cord to a connection box in respecting the polarities as following:
- Live: Brown
- Neutral: Blue
- Earth: Yellow/Green
If you are not sure, it's recommended to ask a qualified electrician for any help and to be sure that
your installation is in accordance with the local regulations.
(FAN) to
(LOW) or
(HIGH) to choose the desired power:
1
2
3
4
(FAN) to activate

Advertisement