Commissioning, inspection, maintenance
Commissioning the system
Commissioning assistant
sequence
Heating circuit 2, 3 ...
DHW
Not available
Cylinder with one sensor System with DHW cylinder with 1 cylinder temperature sensor
Cylinder with one sensor
and DHW circulation
pump
Loading cylinder with
two sensors
Loading cylinder with
two sensors and DHW
circulation pump
Low loss header/buffer cyl-
inder
Not available
Low loss header, heating
only
DHW heating upstream
of low loss header
DHW heating down-
stream of low loss head-
er
Buffer cylinder, heating
only
DHW heating upstream
of buffer cylinder
DHW heating down-
stream of buffer cylinder
Solar
(if installed)
No solar function
Solar function DHW
heating
Solar function for central
heating backup
Solar function with pre-
heating, 2nd cylinder
Solar function with ther-
mostat function
Solar function with cycli-
cal heating
32
(cont.)
Explanations and references
Heating circuits with mixer or heating circuits with mixer with external hook-up
(if installed)
Settings for DHW heating according to the system components
System without DHW heating
System with DHW cylinder with 1 DHW cylinder temperature sensor and
DHW circulation pump
Gas condensing storage combi boiler or gas/solar condensing storage combi
boiler with integral loading cylinder
Gas condensing storage combi boiler or gas/solar condensing storage combi
boiler with integral loading cylinder with DHW circulation pump
Settings for the consumer circuits according to the system components
There is no low loss header or heating water buffer cylinder in the system.
System with low loss header, without DHW heating
DHW heating with e.g. separate DHW cylinder connected upstream of the low
loss header
DHW heating with e.g. separate DHW cylinder connected downstream of the
low loss header
System with heating water buffer cylinder, without DHW heating
DHW heating with e.g. separate DHW cylinder connected upstream of the
heating water buffer cylinder
DHW heating with e.g. separate DHW cylinder connected downstream of the
heating water buffer cylinder
Solar thermal system connected to heat generator via EM-S1 extension
(ADIO, SDIO/SM1A electronics module)
Setting subject to the design of the solar thermal system
EM-S1 extension installation and service instructions
Only adjustable on SDIO/SM1A electronics module
Only adjustable on SDIO/SM1A electronics module
Only adjustable on SDIO/SM1A electronics module
Only adjustable on SDIO/SM1A electronics module