Other Alarm Visual And Audible Indicators - Kidde 900-CUDR User Manual

Combination photoelectric smoke & carbon monoxide alarm
Table of Contents

Advertisement

3. Other Alarm Visual And Audible Indicators

Operational Mode
Normal (standby)
Test (button press when
no alarm condition is
present)
(Note: Test is very loud,
stand a few feet away.)
Smoke or CO Alarm
Memory (unit has
experienced a smoke or
CO alarm event, or has
detected 100ppm CO or
greater.)
Smoke Alarm Hush
TM
Mode
CO Alarm Reset
6
Visual Indications
Green LED blinks approx every
60 sec.
Red LED blinks in time with
alarm pattern.
Smoke: Red LED blinks
every 15 sec.
CO: 2 red LED blinks
every 15 sec.
Red LED blinks every 2 sec.
None.
Audible Indications
• Single beep.
• 3 long beeps, pause, 3 long beeps,
4 quick beeps, pause, 4 quick beeps.
After button push, smoke alarm
pattern stops. (If there is too much
smoke to allow Hush
TM
, smoke alarm
pattern continues.)
After button push: CO alarm pattern
stops.
Action/Note
Perform button press once a week to
verify proper alarm operation.
NOTE: Alarm memory is only retained
for 24 hrs.
Push button to clear Alarm Memory.
This feature is to be used only when
a known alarm condition, such as
smoke from cooking, activates the
alarm.
TM
Push button during Hush
to clear
Hush
TM
and perform a test.
Unit is confirming if CO is present or
if it experienced a nuisance situation.
Re-alarm means danger. Move to fresh
air and call 911.