5800 Series Transmitter Input Loop Identification

• All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each
of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
• Transmitter inputs entered as:
"RF" (Supervised RF) Type send periodic check-in
signals, as well as fault, restore and low battery signals.
The transmitter must remain within the receiver's range.
"UR" (Unsupervised RF) Type send all the signals that
the "RF" Type does, but the control does not supervise
the check-in signals. The transmitter may, therefore, be
carried off-premises.
"BR" (Unsupervised Button RF) Type only send fault
signals. They do not send restore or check-in signals.
They will indicate a low battery condition when tested or
activated normally. The transmitter may be carried off-
premises.
Note: For information on any transmitter not shown
above, refer to the instructions accompanying that
transmitter for details regarding loop numbers, etc.
UL NOTE:
The following transmitters are not intended for
use in UL installations: 5802MN, 5802MN2, 5804, 5804BD,
5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850.
The 5827BD and 5800TM can be used in UL Listed
Residential Burglar installations.
Wireless Key Predefined Default Templates
For 5804
Loop
TEMPLATE 1
1
2
3
4
TEMPLATE 2
1
2
3
4
TEMPLATE 3
1
2
3
4

Table of Device Addresses

This Device
RF Receiver
Long Range Radio
4286 Voice Module
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 zones 33 - 40
module 5 zones 41 - 48
Relay Modules (4204):
module 1
module 2
module 3
module 4
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
5800TM Module
††
Addressable devices are identified by "1" plus the device address when reporting. Enter report code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
Function
Zone Type
No Response
23
Disarm
22
Arm Away
21
No Response
23
No Response
23
Disarm
22
Arm Away
21
Arm Stay
20
24-hour audible
7
Disarm
22
Arm Away
21
Arm Stay
20
Uses Address Reports as †† Enabled By...
00
100
03
103
04
104
07
107
08
108
09
109
10
110
11
111
12
112
13
113
14
114
15
115
16
n/a
17
n/a
18
n/a
19
n/a
20
n/a
21
n/a
22
n/a
23
n/a
28
n/a
LOOP 3
LOOP 4
YOU MUST
ENROLL
LOOP 2
THIS
LOOP 1
BUTTON
5 8 0 1
ENROLL AS
ENROLL AS
"UR" OR "RF"
"UR" OR "RF"
LOOP 1
5808
ENROLL AS "RF"
LOOP 1
5809
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 2
LOOP 2
(REED)
(REED)
LOOP 3
(TERMINALS)
LOOP 1
LOOP 3
(TERMINALS)
(TERMINALS)
5 8 1 9
ENROLL AS "RF"
For 5804BD
Loop
TEMPLATE 4
TEMPLATE 5
TEMPLATE 6
*56 zone programming: input device type entry
automatic if output to long range radio field *29 enabled
automatic if phone module access code field *28 enabled
*56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
data field programming as listed below:
always enabled, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
automatic
– 15 –
LOOP 3
LOOP 4
O N
YOU MUST
O F
LOOP 2
F
ENROLL
LOOP
THIS
LOOP 1
1
BUTTON
LOOP 3
5802MN
5804
ENROLL AS "BR"
LOOP 2
LOOP 2
(REED)
(REED)
LOOP 1
LOOP 1
(TERMINALS)
ALTERNATE
(TERMINALS)
POSITION
FOR LOOP 2
5816
5816MN
ENROLL AS "RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
(Green)
(Red)
(Yellow)
5819S (WHS & BRS)
5850 (GBD)
ENROLL AS "RF"
ENROLL AS "RF"
Function
Zone Type
1
No Response
2
No Response
3
Arm Away
4
Disarm
1
No Response
2
Arm Stay
3
Arm Away
4
Disarm
1
24-hour audible
2
Arm Stay
3
Arm Away
4
Disarm
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
LOOP 1
SET
HOUSE
CODE
5 8 0 4 B D
ENROLL AS "BR"
LOOP 1
(PRIMARY)
LOOP 2
(AUX.
CENTER)
LOOP 3
(AUX.
RIGHT)
5817
ENROLL AS "RF"
LOOP
1
MOTION
5890
ENROLL AS
"RF" OR "RM"
V20P-006-V0
23
23
21
22
23
20
21
22
7
20
21
22

Hide quick links:

Advertisement

Table of Contents
loading