Tripp Lite SmartOnline AGPS8294 Series Owner's Manual page 14

Single-phase rackmount online ups systems with built-in lcd monitoring & control screen
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Operations
Power Strategy Operating Features and Supported UPS Operating Modes
The configured UPS Power Strategy provides a framework for UPS operation as it switches between operating modes as dictated by
power events and UPS status. Each Power Strategy offers a unique set of operating parameters that the UPS adheres to in order to
meet user preferences for high-performance or high efficiency. Additional frequency regulation and conversion options are also available
for advanced applications. The chart below lists the UPS operating modes supported for each Power Strategy option.
AUTO ADAPTIVE
UPS runs continuously in
ECONOMY MODE after
running in ONLINE MODE
for one continuous week
without a power failure.
MAX. QUALITY
UPS runs in ONLINE MODE
continuously to maintain
the highest quality output
power for connected
equipment.
MAX. EFFICIENCY
UPS runs in ECONOMY
MODE full time when input
is within the bypass range.
FREQUENCY
REGULATION
UPS regulates output
to within +/-0.05Hz of
nominal.
FREQUENCY
CONVERSION to 60Hz
UPS converts 50Hz input
to 60Hz.
(+/-0.05Hz)
FREQUENCY
CONVERSION to 50Hz
UPS converts 60Hz input
to 50Hz.
(+/-0.05Hz)
* LCD displays FREQUENCY REGULATION as the operating mode with derating information.
** LCD displays FREQUENCY CONVERSION as the operating mode with derating information.
UPS OPERATING MODES
UPS automatically switches operating modes as dictated by the configured power strategy, current
power and UPS status conditions.
Support for
Support for
ONLINE MODE
ECONOMY MODE
YES. When input is within
YES. When input is within
the ONLINE voltage range,
the ECONOMY MODE
but outside the BYPASS
voltage range and there
voltage range, and after
are no power failures for
AC power is restored.
one week.
YES. When input is within
NO.
the ONLINE voltage range.
YES. When input is within
YES. When input is within
the ONLINE voltage range,
the ECONOMY MODE
but outside the BYPASS
voltage range.
voltage range.
YES. When input is within
NO.
the ONLINE voltage
range.*
YES. When input is within
NO.
the ONLINE voltage
range.**
YES. When input is within
NO.
the ONLINE voltage
range.**
Support for
BATTERY MODE
YES.
YES.
YES.
YES.
YES.
YES.
14
Support for
AUTO-BYPASS
YES. In the event of
UPS inverter fault while
input voltage is within the
BYPASS voltage range.
YES. In the event of
UPS inverter fault while
input voltage is within the
BYPASS voltage range.
YES. In the event of
UPS inverter fault while
input voltage is within the
BYPASS voltage range.
YES. In the event of
UPS inverter fault while
input voltage is within the
BYPASS voltage range.
NO.
NO.

Advertisement

Table of Contents
loading

Table of Contents