Moxa Technologies MGate EIP3000 User Manual

Moxa Technologies MGate EIP3000 User Manual

Df1 to ethernet/ip gateway
Hide thumbs Also See for MGate EIP3000:

Advertisement

Quick Links

TM
MGate
EIP3000 DF1 to EtherNet/IP Gateway
User's Manual
First Edition, June 2009
www.moxa.com/product
© 2009 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGate EIP3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Moxa Technologies MGate EIP3000

  • Page 1 MGate EIP3000 DF1 to EtherNet/IP Gateway User’s Manual First Edition, June 2009 www.moxa.com/product © 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx...
  • Page 2 MGate EIP3000 DF1 to EtherNet/IP Gateway User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright © 2009 Moxa Inc.
  • Page 3: Table Of Contents

    Table of Contents Chapter 1 Introduction ....................1-1 Overview ..........................1-2 Package Checklist......................... 1-2 Product Features ........................1-3 Chapter 2 Getting Started ..................2-1 Connecting Power ........................ 2-2 Connecting Serial Devices....................2-2 Connecting to a Host or the Network ................... 2-2 Installing the Software......................2-3 Mounting the Unit ........................
  • Page 4 Monitoring EtherNet/IP Activity ..................5-17 Open Traffic Monitor Window................... 5-18 Filter Traffic Information ................... 5-19 Save Log to File......................5-20 Upgrading Firmware ......................5-20 Chapter 6 Pin Assignments ..................6-1 DB9 (Male)........................... 6-2 Terminal Block (RS-422) ..................... 6-3 Power Input, Relay Output ....................6-3 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx...
  • Page 5: Chapter 1 Introduction

    Introduction Chapter 1 Welcome to the MGate EIP3000 line of DF1 to EtherNet/IP gateways. All models feature easy protocol conversion from DF1 to EtherNet/IP, and RS-232/422 ports for DF1 communication. One-port and two-port models are available. This chapter is an introduction to the MGate EIP3000 and includes the following sections:...
  • Page 6: Overview

    Windows utilities for easy setup and traffic monitoring A Windows utility is provided to make configuration and operation of the MGate EIP3000 as easy as possible. The utility automatically connects to all available MGate EIP3000 units on the LAN for you.
  • Page 7: Product Features

    MGate EIP3000 Series User’s Manual Introduction Product Features PCCC objects for Rockwell Automation networks supported. 8 simultaneous EtherNet/IP clients with up to 16 simultaneous requests per client. Serial redirector function provided. ProCOM function provides virtual serial port for multiple DF1 and EtherNet/IP device communication.
  • Page 8: Chapter 2 Getting Started

    Getting Started Chapter 2 This chapter provides basic instructions for installing the MGate EIP3000. The following topics are covered: Connecting Power Connecting Serial Devices Connecting to a Host or the Network Installing the Software Mounting the Unit RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 9: Connecting Power

    MGate EIP3000 Series User’s Manual Getting Started Connecting Power The unit can be powered using the AC adaptor or by connecting a power source to the terminal block, depending on the model. The following instructions are for the AC adaptor: 1.
  • Page 10: Installing The Software

    MGate EIP3000 Series User’s Manual Getting Started Installing the Software The Windows management utility is installed from the Document and Software CD. Follow the onscreen instructions after inserting the CD. Mounting the Unit The unit can be mounted on the wall or mounted on a DIN-Rail.
  • Page 11: Hardware: Eip3170, Eip3170I

    Hardware: EIP3170, EIP3170I Chapter 3 This chapter provides hardware information for the MGate EIP3170 and EIP3170I. The following topics are covered: Panel Layout LED Indicators Dimensions Jumpers Pin Assignments DB9 (Male) Terminal Block (RS-422) Power Input, Relay Output DIN-Rail, Wall Mounting Specifications RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx...
  • Page 12: Panel Layout

    MGate EIP3000 Series User’s Manual Hardware: EIP3170, EIP3170I Panel Layout LED Indicators Name Color Function PWR1 Power is being supplied to the power input. PWR2 Power is being supplied to the power input. Steady on: Power is on and unit is booting up.
  • Page 13: Dimensions

    MGate EIP3000 Series User’s Manual Hardware: EIP3170, EIP3170I Dimensions 29 mm (1.14 in) 14.5 mm (0.57 in) 14.5 mm (0.57 in) 89.2 mm (3.51 in) 20.6 mm 29.91 mm (0.81 in) (1.18 in) 11.5 mm (0.45 in) 25.9 mm 35 mm (1.02 in)
  • Page 14: Jumpers

    Switch 4 on the port’s assigned DIP switch is reserved. ATTENTION Do not use the 1 KΩ pull high/low setting on the MGate EIP3000 when using the RS-232 interface. Doing so will degrade the RS-232 signals and reduce the effective communication distance.
  • Page 15: Pin Assignments

    MGate EIP3000 Series User’s Manual Hardware: EIP3170, EIP3170I Pin Assignments DB9 (Male) The MGate EIP3170 and EIP3170I use a DB9 (male) serial port for RS-232 connections to DF1 devices. RS-232 Terminal Block (RS-422) The MGate EIP3170 and EIP3170I use a terminal block connector for RS-422 connections to DF1 devices.
  • Page 16: Power Input, Relay Output

    MGate EIP3000 Series User’s Manual Hardware: EIP3170, EIP3170I Power Input, Relay Output Shielded DC Power DC Power Relay Relay DC Power DC Power Ground Input 1 Input 1 Output Output Input 2 Input 2 DIN-Rail, Wall Mounting There are two sliders on the back of the unit for DIN-Rail and wall mounting.
  • Page 17: Specifications

    MGate EIP3000 Series User’s Manual Hardware: EIP3170, EIP3170I Specifications Ethernet 10/100 Mbps, RJ45, Auto MDI/MDIX Protection Built-in 1.5 KV magnetic isolation Serial Interface Interface RS-232/422 No. of Ports 1 port Connector Type DB9 (male) for RS-232, terminal block for RS-422...
  • Page 18: Hardware: Eip3270, Eip3270I

    Hardware: EIP3270, EIP3270I Chapter 4 This chapter provides hardware information for the MGate EIP3270 and EIP3270I. The following topics are covered: Panel Layout LED Indicators Dimensions Jumpers Pin Assignments DB9 (Male) Power Input, Relay Output DIN-Rail, Wall Mounting Specifications RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx...
  • Page 19: Panel Layout

    MGate EIP3000 Series User’s Manual Hardware: EIP3270, EIP3270I Panel Layout LED Indicators Name Color Function Power is being supplied to the power input. PWR1 Power is being supplied to the power input. PWR2 Steady on: Power is on and unit is booting up.
  • Page 20: Dimensions

    MGate EIP3000 Series User’s Manual Hardware: EIP3270, EIP3270I Dimensions 29 mm (1.14 in) 14.5 mm (0.57 in) 14.5 mm 89.2 mm (3.51 in) (0.57 in) 20.6 mm 29.91 mm (0.81 in) (1.18 in) 11.5 mm (0.45 in) 25.9 mm 35 mm (1.02 in)
  • Page 21: Jumpers

    Switch 4 on the port’s assigned DIP switch is reserved. ATTENTION Do not use the 1 KΩ pull high/low setting on the MGate EIP3000 when using the RS-232 interface. Doing so will degrade the RS-232 signals and reduce the effective communication distance.
  • Page 22: Pin Assignments

    MGate EIP3000 Series User’s Manual Hardware: EIP3270, EIP3270I Pin Assignments DB9 (Male) The MGate EIP3000 uses DB9 (male) serial ports to connect Modbus RTU or ASCII devices. Each port supports two serial interfaces: RS-232 and RS-422. RS-232 RS-422 TxD- TxD+...
  • Page 23: Din-Rail, Wall Mounting

    MGate EIP3000 Series User’s Manual Hardware: EIP3270, EIP3270I DIN-Rail, Wall Mounting There are two sliders on the back of the unit for DIN-Rail and wall mounting. Mounting on a DIN-Rail: Pull out the bottom slider; latch the unit onto the DIN-Rail, and push the slider back in.
  • Page 24: Specifications

    MGate EIP3000 Series User’s Manual Hardware: EIP3270, EIP3270I Specifications Ethernet 10/100 Mbps, RJ45, Auto MDI/MDIX Protection Built-in 1.5 KV magnetic isolation Serial Interface Interface RS-232/422 No. of Ports 2 ports Connector Type DB9 (male) Signals RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND...
  • Page 25: Configuring The Ethernet/Ip Gateway

    Configuring the EtherNet/IP Gateway Chapter 5 We discuss the following topics in this chapter: Installing the Software Starting MGate Manager Change Language Se tting Connecting to the Unit Broadcast Search Specify by IP Addre Modifying the Configur ation Configure IP Address a nd Other Network Settings Configure Serial Communi cation Parameters...
  • Page 26: Installing The Software

    Installing the Software The following instructions explain how to install MGate Manager, a utility for configuring and monitoring MGate EIP3000 units over the network. 1. Insert the Document and Software CD into the CD-ROM drive. Locate and run the following setup program to begin the installation process: MGM_Setup_[Version]_Build_[DateTime].exe...
  • Page 27 MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway 3. When the Select Destination Location window appears, click Next to continue. You may change the destination directory by first clicking on Browse..4. When the Select Additional Tasks window appears, click Next to continue. You may select Create a desktop icon if you would like a shortcut to MGate Manager on your desktop.
  • Page 28 MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway 5. Click Next to start copying the software files. 6. A progress bar will appear. The procedure should take only a few seconds to complete. RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx...
  • Page 29 MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway 7. A message will indicate that MGate Manager is successfully installed. You may choose to run it immediately by selecting Launch MGate Manager. 8. You may also open MGate Manager through Start...
  • Page 30: Starting Mgate Manager

    MGate Manager is a Windows-based utility that is used to configure the MGate EIP3000. Before running MGate Manager, make sure that your PC and the MGate EIP3000 are connected to the same network. Alternatively, the MGate EIP3000 may be connected directly to the PC for configuration purposes.
  • Page 31: Connecting To The Unit

    MGate Manager needs to connect to the unit before the unit can be configured. There are two methods to connect to the unit. Broadcast Search is used to find every MGate EIP3000 on the LAN. Search by IP attempts to connect to a specific unit by IP address, which is useful if the unit is located outside the LAN or can only be accessed by going through a router.
  • Page 32: Specify By Ip Address

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway When the search is complete, every MGate EIP3000 that is found on the LAN will appear in the window with MAC address and IP address. Simply select the one that you wish to configure.
  • Page 33: Modifying The Configuration

    Try doing the search again and re-entering the IP address carefully. Another possibility is that the MGate EIP3000 is located on the same LAN as your PC, but on a different subnet. In this case, you can modify your PC’s IP address and or netmask so that it is on the same subnet as the MGate EIP3000.
  • Page 34: Configure Ip Address And Other Network Settings

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway Configure IP Address and Other Network Settings The Network tab is where the unit’s network settings are configured. You can modify the Name, Network Configuration, IP1 Address, IP2 Address (only for 2-port model) and the default IP1 address is 192.168.127.254, IP2 address is 192.168.127.253, Netmask and Default...
  • Page 35 MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway Parameter Value Notes You can set a password to prevent unauthorized users from configuring the unit. The password will be required when Password (an alphanumeric string) anyone attempts to configure the unit over the network.
  • Page 36: Configure Serial Communication Parameters

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway ATTENTION To erase an existing password, leave both the New Password and Confirm Password text input boxes blank. The password will be erased when you click OK in the bottom right corner.
  • Page 37: Set Up Routing And Procom Function

    How to set Routing on the MGate EIP3000 The MGate EIP3000 decides where to forward the received requests according to its internal routing rules. The internal routing rules are set on the Routing page. Two kinds of routing rules can be used.
  • Page 38 EtherNet/IP communication. This is an intelligent function of the Fieldbus gateway that translates the data to the correct destination through DF1 protocol. How to set ProCOM on the MGate EIP3000 ProCOM is your best solution if your system requires using a remote PC that only supports DF1 protocol to control remote DF1 devices.
  • Page 39: Set Up Protocol

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway target DF1 device, it will forward the response to ProCOM and then the application running on your PC will receive the response. Set up Protocol You can configure the options for DF1, EtherNet/IP, and CIP protocol. Response Time-out defines how much time the EIP3000 needs to wait for a response after sending a PCCC command to a DF1/EIP device.
  • Page 40: Set Up Miscellaneous

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway Set Up Miscellaneous This page defines all other options that can not be classified. Currently, this page defines “Auto Relay Warning”, “Reset Button Protect” and “Telnet Console”. The auto relay warning includes power failure, Ethernet 1 or 2 links down to trigger relay warning.
  • Page 41: Verifying Location Of Unit

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway Verifying Location of Unit If you are managing multiple MGate units, you may wonder if you are configuring the correct unit in MGate Manager. You can select a unit in MGate Manager and click Locate to make that unit’s “Ready”...
  • Page 42: Open Traffic Monitor Window

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway Open Traffic Monitor Window Select the unit that you wish to monitor and click Monitor to open the Traffic Monitor window. In the Traffic Monitor window, click Start to begin live monitoring of the data passing through the selected MGate EIP3000 unit.
  • Page 43: Filter Traffic Information

    MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway To stop capturing the log, press the Stop button. Filter Traffic Information By default, all events are displayed in the traffic monitor window. MGate Manager also allows the data to be filtered so only the relevant information is displayed. The filter is selected using the radio buttons and customized using the “Filter info”...
  • Page 44: Save Log To File

    After you have downloaded the new firmware onto your PC, you can use MGate Manager to write it onto your MGate EIP3000. Select the desired unit from the list in MGate Manager and click Upgrade Firmware to begin the process.
  • Page 45 MGate EIP3000 Series User’s Manual Configuring the EtherNet/IP Gateway The dialog boxes will guide you through the process. You will need to browse your PC for the firmware file. Make sure that it matches your model. As the firmware is written to the unit, progress is displayed in the window.
  • Page 46: Chapter 6 Pin Assignments

    Pin Assignments Chapter 6 We discuss the following topics in this chapter: DB9 (Male) Terminal Block (RS-422) Power Input, Relay Output RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx...
  • Page 47: Db9 (Male)

    MGate EIP3000 Series User’s Manual Pin Assignments DB9 (Male) The MGate EIP3000 uses DB9 (male) serial ports to connect DF1 devices. Each port supports two serial interfaces: RS-232 and RS-422. RS-232 RS-422 TxD- TxD+ RxD+ RxD- EIP3170, EIP3170I RS-232 RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 48: Terminal Block (Rs-422)

    MGate EIP3000 Series User’s Manual Pin Assignments Terminal Block (RS-422) The EIP3170 and EIP3170I have a terminal block connector for RS-422 signal. RS-422 TxD+ TxD- RxD+ RxD- Power Input, Relay Output Shielded DC Power DC Power Relay Relay DC Power...