4.1

Blower operation

A blower is already installed on this insert. It is located
at the bottom of the insert. Its function is to increase
airflow through the heat exchanger and improve hot
air circulation in the room. When used regularly, the
blower can provide a small increase in efficiency, up
to 2%. However, the use of a blower should not be
used as a way to gain more output from an insert that
is undersized for the space it is intended to heat.
Ensure the blower cord is not in contact
with any surface of the insert to prevent
electrical shock or fire damage. Do not
run cord beneath the insert.
4.2

Fire Screen

This insert has been tested for use with an open door in conjunction with a fire screen, sold
separately. The fire screen must be properly secured on the insert to avoid any risk of sparks
damaging the flooring. When the fire screen is in use, do not leave the insert unattended to
respond promptly in the event of smoke spillage into the room. Potential causes of smoke
spillage are described in Section
Optional Fire Screen Installation»
Operating the insert with a fire screen increases possibilities of generating carbon monoxide. Carbon
monoxide is an odourless gas that is highly toxic which can cause death at high concentration in
air. Installation of a carbon monoxide detector is highly recommended.

5. Burning Wood Efficiently

5.1

First Use

Two things happen when burning the first few fires; the paint cures and the internal components are
conditioned. As the paint cures, some of the chemicals vaporize. The vapors are not poisonous,
but they smell bad. Fresh paint fumes can also trigger false alarms in smoke detectors. When
lighting the heater for the first few times, it may be wise to open doors and windows to ventilate
the house.
Page 16
The blower has a variable speed control that can be
adjusted in three different positions; either from high (HI) to
low (LO) or closed (OFF). Allow the insert to reach operating
temperature (approximately one hour) before turning on
the blower, since increased airflow from the blower will
remove heat and affect the start up combustion efficiency.
The blower is equipped with a heat sensor. Therefore, the
switch can be left in the automatic position (1). The blower
will start automatically when the insert is hot enough and it
will stop when the insert has cooled down. The switch can
also be set to the manual position (3) to turn on the blower
manually and have it run continuously. The position (2)
stops the blower and prevent it from starting automatically
when the insert is hot enough.