- from intercommunicating apartment
To associate the ringtone to the type of call, press for a
long time key:
to associate it to the call from external station
to associate it to the call from intercommunicating
block of flats
to associate it to the call from floor
to associate it to the call from intercommunicating
apartment
3.2.6 Exit from the ringtone programming mode
Wait about 10 seconds without pressing any key; the device
exits automatically from the programming mode and icon
turns off.
4. PROGRAMMING
To function properly, the video intercom must be programmed;
if no special performance are required the only needed
programming is that related to the user address, in this case
pass directly to paragraph 4.2.1 User Address and number
of room.
Attention: the programming must be performed by expert
(installer), incorrect programming can prevent proper
operation of the entire video intercom system.
All the programming described below (with the exception
of those relating to paragraph 4.2.1) and including those of
paragraph 3.2 "Ringtones" can be performed via Bluetooth
with a Smartphone or a Tablet (PGR2991BT programmer or
XE2921/XE2922 expansion cards required) using the "DUO
System" Application. The application can be downloaded from
the following links:
for iOS
https://farfisa.com/qr/ios-duo/
for Android
https://farfisa.com/qr/and-duo/
The programming can also be done manually as described
in the following paragraphs:
4.1 System programming
The programming that can be performed are:
- addresses associated to the key
- address associated to the key
- call re-launch address from floor
- secondary addresses of the video intercom
For programming, follow the methods described in the
following paragraphs.
4.1.1 Entering into the system programming
For accessing to the system programming jumper J4 must
be moved from position 2-3 to position 1-2; icon
4.1.2 Addresses associated to
To key
of room for intercommunicating calls, or 1 actuator address
or up to 4 addresses of external stations to be able to control
them in sequence.
- Programming building Intercommunicating Address:
- Programming Apartment Intercommunicating Address:
- Programming Actuator Address:
- Programming External Station Addresses:
To change the stored addresses, it is necessary to exit
from the programming, wait 3 seconds and re-enter in
programming; with SW1 set the new address, leaving
SW2 at 0 and press for a long time key
will confirm the occurred storing of the new first address;
proceed in a similar manner to change the eventual second,
third and fourth address. To delete the stored addresses, it
is necessary to set code 255 on SW1 and 0 on SW2 (see
table on page 39) and press for a long time key
a tone will confirm the occurred cancellation of the first
address; proceed in a similar way to cancel any second,
third and fourth stored address.
4.1.3 Addresses associated to
To key
of room for intercommunicating calls, or 1 actuator address.
- Programming building Intercommunicating Address:
(211 by default)
- Programming Apartment Intercommunicating Address:
- 15 -
can be associated 1 address of apartment and
with microswitches SW1 set the address of the desired
apartment and with microswitches SW2 set the room
number 0 (see table on page 39); press for a long time
key
until a tone will confirm the occurred storing.
with microswitches SW1 set the address of your apartment
and with microswitches SW2 set room number, from 0 to
3 (see table page 39; press for a long time key
a tone will confirm the occurred storing.
with microswitches SW1 set the actuator address which is
intended to control (from 211 to 230) and with microswitches
SW2 set the room number 0 (see table on page 39);
press for a long time key
occurred storing.
in the key
, it is possible to programme up to 4 addresses
of external stations with which it will be connected in
sequence at each pressure of the key. With micro-switches
SW1 set the address of the first external station, and set 0
on microswitches SW2, (see table on page 39); press for
a long time key
until a tone will confirm the occurred
storing of the first address. If it is intended to programme
a second address, it is necessary to set microchips SW1
with the address of the second external station leaving at
0 microswitches SW2 (see table on page 39) and press
for a long time key
until two tones will confirm the
occurred storing of the second address. Proceed in a
similar manner to the programming of the third and fourth
external station address, the occurred programming is
confirmed respectively by three or four tones.
can be associated 1 address of apartment and
with microswitches SW1 set the address of the desired
apartment and with microswitches SW2 set the room
number 0 (see table on page 39); press for a long time
key
until a tone will confirm the occurred storing.
with microswitches SW1 set the address of your apartment
and with microswitches SW2 set room number, from 0 to
3 (see table page 39); press for a long time key
a tone will confirm the occurred storing.
lights up.
key
until
until a tone will confirm the
until a tone
until
key
until
Mi 2567